{"id":88849,"date":"2026-09-04T02:00:49","date_gmt":"2026-09-04T02:00:49","guid":{"rendered":"https:\/\/www.harsle.com\/?post_type=docs&#038;p=88849"},"modified":"2026-09-04T02:53:43","modified_gmt":"2026-09-04T02:53:43","password":"","slug":"estun-e315p-system-parameters","status":"publish","type":"docs","link":"https:\/\/www.harsle.com\/de\/docs\/estun-e315p-system-parameters\/","title":{"rendered":"How to Manage ESTUN E315P System Parameters Easily?"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Properly managing <a href=\"https:\/\/www.youtube.com\/watch?v=GwlCHLs7I6U&amp;t=157s\" data-type=\"link\" data-id=\"https:\/\/www.youtube.com\/watch?v=GwlCHLs7I6U&amp;t=157s\" target=\"_blank\" rel=\"noopener\">ESTUN E315P<\/a> System Parameters helps operators and technicians adapt the controller to different press brake operating requirements. The System Parameters interface contains settings related to display units, step transitions, safety devices, pressure-holding signals, jog movement, step counting, X-axis safety distance, and system information.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Although some parameters only affect the interface, others directly influence how the press brake responds during a bending cycle. Understanding each setting before making changes is therefore important for both efficient operation and machine safety.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This guide explains the main ESTUN E315P System Parameters, their available options, and how they affect press brake operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to Access ESTUN E315P System Parameters<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"998\" height=\"561\" src=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5.png\" alt=\"ESTUN E315P System Parameters\" class=\"wp-image-88863\" srcset=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5.png 998w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5-18x10.png 18w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5-360x202.png 360w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5-400x225.png 400w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5-767x431.png 767w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5-429x241.png 429w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5-149x84.png 149w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/09\/image-5-699x393.png 699w\" sizes=\"(max-width: 998px) 100vw, 998px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The System Parameters page is located in the controller&#8217;s <strong>Einstellungen<\/strong> section. This interface provides access to the additional system settings described in the E315P manual.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The available items include Language, Length Unit, Continue Enable, Light Curtain Enable, LDP Enable, Jog, Step Mode, X Safe Distance, Bending Type Select, and Software Version.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before modifying any ESTUN E315P System Parameters, technicians should record the existing configuration. Parameters related to machine movement or safety should always correspond to the actual electrical and mechanical configuration of the press brake.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to Set Language and Length Unit<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Two of the most basic system parameters control the interface language and measurement unit.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sprache<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Der <strong>Sprache<\/strong> parameter allows the operator to select the controller interface language.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Available options are:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>chinesisch<\/li>\n\n\n\n<li>Englisch<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The default setting shown in the manual is Chinese.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This parameter only determines the language displayed on the controller interface and can be selected according to the operator&#8217;s requirements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Length Unit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Der <strong>Length Unit<\/strong> parameter determines whether dimensional values are displayed in:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>mm<\/strong><\/li>\n\n\n\n<li><strong>Zoll<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The default setting is <strong>mm<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An important feature of this parameter is automatic value conversion. When the unit is changed, the E315P automatically converts the related length values.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This allows operators to change between metric and imperial units without manually recalculating every associated dimensional parameter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Does Continue Enable Control?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Continue Enable<\/strong> determines how the machine proceeds from one step to the next during transitions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The parameter provides two options:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Disable:<\/strong> The operator must press the foot pedal to proceed to the next step during transitions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Enable:<\/strong> The controller automatically completes the transition without requiring additional foot pedal input.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This makes Continue Enable one of the ESTUN E315P System Parameters that directly affects the operating sequence rather than simply changing the controller display.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When selecting this option, operators should consider the required production process and how they want the machine to transition between programmed steps.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does Light Curtain Enable Work?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der <strong>Light Curtain Enable<\/strong> parameter is associated with the press brake safety light curtain.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Its available settings are:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Deaktivieren<\/li>\n\n\n\n<li>Aktivieren<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The default value is Disable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before enabling this function, the safety light curtain must be connected and labeled according to the machine&#8217;s electrical diagram. The corresponding input should be configured as the <strong>Safety Signal<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When Light Curtain Enable is active, the E315P monitors this safety input.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W\u00e4hrend der <strong>Fast Closing<\/strong> phase, if the safety signal changes due to actual wiring and safety-device operation, the slider stops immediately.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because this function is directly related to machine safety, it should only be enabled when the actual light curtain and corresponding electrical signal have been correctly installed and configured.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Does LDP Enable Change?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der <strong>LDP Enable<\/strong> parameter determines which signal is used to start the pressure-holding time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LDP refers to the <strong>Lower Dead Point Signal for Pressure Holding Impact<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When the setting is <strong>Deaktivieren<\/strong>, pressure-holding time begins when the <strong>Speed Change Signal<\/strong> changes from OFF to ON.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When the setting is <strong>Aktivieren<\/strong>, pressure-holding time begins when the <strong>Lower Dead Point Signal<\/strong> changes from OFF to ON.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, this setting changes the trigger condition used by the controller for pressure holding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When managing ESTUN E315P System Parameters, LDP Enable should be configured according to the machine&#8217;s actual signal arrangement and bending sequence.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does the Jog Parameter Affect Slider Speed?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der <strong>Joggen<\/strong> parameter determines whether the Speed Change Signal influences slider speed during downward movement in Jog Mode.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The controller provides two settings: <strong>Close On<\/strong> Und <strong>Close Off<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">When Close On Is Selected<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Slider movement speed is influenced by the Speed Change Signal during downward motion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When the signal is OFF, the slider moves at <strong>fast speed<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When the signal is ON, the slider moves at <strong>slow speed<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">When Close Off Is Selected<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The slider maintains <strong>slow speed regardless of the Speed Change Signal<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This setting is useful for defining how the slider should behave when the machine is being operated in Jog Mode.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Does Step Mode Control?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der <strong>Schrittmodus<\/strong> parameter determines when the <strong>CP counter<\/strong> changes during machine operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Two options are available:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>UDP<\/strong><\/li>\n\n\n\n<li><strong>Composition<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The default setting is UDP.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">UDP Mode<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When UDP is selected, the CP value changes when the slider reaches the <strong>Upper Dead Point<\/strong> w\u00e4hrend des Betriebs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The counter increases or decreases according to the programmed sequence.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Composition Mode<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When Composition is selected, the CP value changes after the slider completes pressure holding and enters the unloading phase.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The main difference is therefore the stage of the bending cycle at which the counter is modified.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Understanding this timing helps technicians select the appropriate Step Mode according to the required operating sequence.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to Set X Safe Distance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>X Safe Distance<\/strong> defines a safety zone for X-axis positioning.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The manual specifies a default value of <strong>45<\/strong>, with an adjustable range of <strong>0.00\u2013999.99 mm\/inch<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When the target X-axis position falls within the defined safety zone, the X-axis maintains <strong>low-speed movement during positioning<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The diagram in the manual shows this safety area beginning from the X-axis minimum position and extending for the specified safe distance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is an important distinction: X Safe Distance does not simply define the entire X-axis travel range. Instead, it establishes an area where positioning movement is maintained at a lower speed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When adjusting this value, technicians should consider the actual backgauge configuration and machine movement requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Are Bending Type Select and Software Version?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The final items in the ESTUN E315P System Parameters interface provide information about the current controller configuration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Bending Type Select<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bending Type Select<\/strong> indicates the current synchronization mode.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Unlike settings such as Continue Enable or X Safe Distance, its primary purpose in this section is to show the synchronization mode currently being used.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Software Version<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Der <strong>Software Version<\/strong> item displays the software versions of the upper and lower controllers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This information can be useful when checking the controller configuration or identifying the installed software version during technical support and maintenance.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Should You Check Before Changing System Parameters?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Not all ESTUN E315P System Parameters have the same level of impact.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Changing the interface language or measurement unit is relatively straightforward, while parameters such as Light Curtain Enable, LDP Enable, Jog, Step Mode, and X Safe Distance can influence machine behavior.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before modifying these parameters, technicians should confirm the actual machine configuration and record the original settings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Particular attention should be given to parameters involving external signals. For example, Light Curtain Enable depends on the correct safety-device wiring, while LDP Enable depends on the signal used to trigger pressure holding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Settings should therefore be based on the actual electrical configuration and operating requirements of the press brake rather than copied directly from another machine.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Managing ESTUN E315P System Parameters Effectively<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The ESTUN E315P System Parameters interface combines basic controller preferences with settings that affect the bending sequence and machine movement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Language and Length Unit allow the interface to match operator preferences. Continue Enable controls step transitions, while Light Curtain Enable integrates the configured safety light curtain into the Fast Closing phase. LDP Enable determines the pressure-holding trigger, and Jog defines how the Speed Change Signal affects manual downward movement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Step Mode controls when the CP counter changes, while X Safe Distance establishes a low-speed positioning area for the X-axis. Bending Type Select and Software Version provide additional system information.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Understanding these differences allows technicians to manage the controller more efficiently while avoiding unnecessary changes to parameters that directly affect machine operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions\uff08FAQ\uff09<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-1788426957997\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Should I Back Up the Parameters Before Making Changes?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Yes. Recording or backing up the original settings is recommended before modifying machine-related parameters. This is especially useful during commissioning or troubleshooting because the previous configuration can be referenced if an adjustment produces unexpected results.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1788426988877\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What Should I Check If the Safety Light Curtain Does Not Stop the Slider?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>First confirm that the light curtain is correctly installed and wired according to the electrical diagram. Then verify that its input is assigned to the appropriate Safety Signal and that the corresponding function is enabled. Safety-related problems should be resolved before normal machine operation continues.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1788427001245\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Why Does the X-Axis Move Slowly Near One End?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>This may be related to the configured <strong>X Safe Distance<\/strong>. When the target position is within the defined safety zone, the controller maintains low-speed positioning. Check the target position and current safe-distance value before assuming that the servo system has a speed problem.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Abschluss<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Correctly managing ESTUN E315P System Parameters helps ensure that the controller settings correspond with the actual press brake configuration and operating requirements. While parameters such as Language and Length Unit mainly affect the user interface, other settings influence step transitions, safety signals, pressure-holding logic, jog movement, and X-axis positioning behavior.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before changing machine-related parameters, record the existing values and verify the relevant electrical signals and machine configuration. Particular care should be taken with safety-related settings and parameters that affect the bending sequence.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By understanding the purpose of each ESTUN E315P System Parameters setting and avoiding unnecessary changes, operators and technicians can configure the controller more effectively and simplify future troubleshooting.<\/p>","protected":false},"excerpt":{"rendered":"<p>Properly managing ESTUN E315P System Parameters helps operators and technicians adapt the controller to different press brake operating requirements. The<\/p>","protected":false},"author":32,"featured_media":88857,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[3249],"doc_tag":[3549,5631,6014],"knowledge_base":[3228],"class_list":["post-88849","docs","type-docs","status-publish","has-post-thumbnail","hentry","doc_category-system-operation","doc_tag-advanced-bending-technology","doc_tag-e315p-press-brake-controller","doc_tag-system-parameters-e315p-press-brake-controller","knowledge_base-press-brake"],"year_month":"2026-09","word_count":1618,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Christina","author_nicename":"christina","author_url":"https:\/\/www.harsle.com\/de\/author\/christina\/"},"doc_category_info":[{"term_name":"System Operation","term_url":"https:\/\/www.harsle.com\/de\/docs\/hydraulic-press\/system-operation\/"}],"doc_tag_info":[{"term_name":"Advanced Bending Technology","term_url":"https:\/\/www.harsle.com\/de\/docs-tag\/advanced-bending-technology\/"},{"term_name":"E315P press brake controller","term_url":"https:\/\/www.harsle.com\/de\/docs-tag\/e315p-press-brake-controller\/"},{"term_name":"System Parameters","term_url":"https:\/\/www.harsle.com\/de\/docs-tag\/system-parameters-e315p-press-brake-controller\/"}],"jetpack_sharing_enabled":true,"knowledge_base_info":[{"term_name":"Press Brake","term_url":"https:\/\/www.harsle.com\/de\/docs\/press-brake\/","term_slug":"press-brake"}],"knowledge_base_slug":["press-brake"],"_links":{"self":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/docs\/88849","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/comments?post=88849"}],"version-history":[{"count":0,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/docs\/88849\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/media\/88857"}],"wp:attachment":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/media?parent=88849"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/doc_category?post=88849"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/doc_tag?post=88849"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/knowledge_base?post=88849"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}