{"id":92356,"date":"2026-11-12T07:32:56","date_gmt":"2026-11-12T07:32:56","guid":{"rendered":"https:\/\/www.harsle.com\/?post_type=docs&#038;p=92356"},"modified":"2026-11-12T07:43:10","modified_gmt":"2026-11-12T07:43:10","password":"","slug":"estun-e315p-jog-mode-settings","status":"publish","type":"docs","link":"https:\/\/www.harsle.com\/de\/docs\/estun-e315p-jog-mode-settings\/","title":{"rendered":"How to Adjust ESTUN E315P Jog Mode Accurately?"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-33e0f240\">Der <strong>ESTUN E315P Jog Mode<\/strong> determines how the press brake controller selects ram movement speed during jog operation. By configuring the Jog parameter, operators can control whether the ram responds to the Speed Change Signal or remains in slow-speed movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fc9972e5\">According to the ESTUN E315P operating manual, the Jog parameter provides two options: Close On and Close Off. These settings determine the relationship between the speed change signal and ram movement during jog operation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-67a7235d\">This guide explains the Jog parameter, its operating logic, configuration procedure, and important precautions for verifying ram movement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is ESTUN E315P Jog Mode?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-96545401\">The ESTUN E315P Jog Mode is a system parameter that determines how the ram&#8217;s movement speed is selected during jog operation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dc213e14\">The parameter is identified as <strong>Joggen<\/strong> in the controller&#8217;s C.2 System Parameters section.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-21037fe9\">According to the operating manual, the specifications are as follows:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Parameter<\/th><th>Spezifikation<\/th><\/tr><tr><td>Parameter Name<\/td><td>Joggen<\/td><\/tr><tr><td>Default Value<\/td><td>Close On<\/td><\/tr><tr><td>Available Options<\/td><td>Close On \/ Close Off<\/td><\/tr><tr><td>Close On<\/td><td>Speed depends on the Speed Change Signal<\/td><\/tr><tr><td>Close Off<\/td><td>Ram operates at slow speed<\/td><\/tr><tr><td>Funktion<\/td><td>Controls jog movement speed selection<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-16f7eb21\">The default setting is Close On.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8039426a\">When this option is selected, the controller uses the Speed Change Signal to determine whether the ram operates at fast or slow speed.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e5c983d4\">When Close Off is selected, the controller uses slow-speed movement regardless of the Speed Change Signal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dfdbabdd\">The parameter does not directly define numerical speed values.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"800\" src=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-1200x800.png\" alt=\"ESTUN E315P Jog Mode\" class=\"wp-image-92450\" srcset=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-1200x800.png 1200w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-400x267.png 400w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-768x512.png 768w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-18x12.png 18w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-360x240.png 360w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-430x287.png 430w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-700x467.png 700w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357-150x100.png 150w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/ESTUN-E315P\u70b9\u52a8\u6a21\u5f0f\u64cd\u4f5c\u6307\u5357.png 1536w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">How Does ESTUN E315P Jog Mode Work?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-75064954\">The ESTUN E315P Jog Mode controls the relationship between the Speed Change Signal and the ram&#8217;s jog movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-93969a58\">The operating manual describes two configurations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Jog Mode: Close On<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-25b49be8\">When Jog is set to Close On, the controller selects the movement speed according to the Speed Change Signal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c862ca4e\">The operating logic is:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-49e93477\"><strong>Speed Change Signal OFF \u2192 Fast Movement<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-15842524\"><strong>Speed Change Signal ON \u2192 Slow Movement<\/strong><\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8c0d913f\">This means that the selected speed changes according to the current state of the relevant signal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ee27f857\">The actual movement speed depends on the machine&#8217;s configured operating parameters.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Jog Mode: Close Off<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-da8c1fe4\">When Jog is set to Close Off, the ram operates at slow speed during jog movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2e71161a\">The controller does not use the Speed Change Signal to switch between fast and slow jog speeds.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6a3e76ef\">This configuration provides a consistent slow-speed selection during jog operation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aa887ebf\">However, selecting Close Off does not establish a specific numerical movement speed or independently guarantee safe machine operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to Configure ESTUN E315P Jog Mode<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-53fc6e38\">Before adjusting the parameter, operators should confirm the machine&#8217;s approved operating configuration and ensure that the ram movement area is clear.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 1: Access System Parameters<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c6dea71f\">Open the ESTUN E315P controller&#8217;s parameter settings.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2c739817\">Locate the <strong>C.2 System Parameters<\/strong> section described in the operating manual.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-959a243e\">Find the parameter labeled <strong>Joggen<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 2: Check the Current Setting<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dc6cb5dd\">Review whether the parameter is set to Close On or Close Off.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-87ee637d\">The factory default is Close On.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-42c94632\">Record the existing setting before making changes, particularly if the machine has already been commissioned.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 3: Select the Required Option<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-97ec359a\">Choose the appropriate ESTUN E315P Jog Mode according to the machine&#8217;s intended operating requirements.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d82b93b5\">W\u00e4hlen <strong>Close On<\/strong> when jog movement speed should respond to the Speed Change Signal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-429da8dc\">W\u00e4hlen <strong>Close Off<\/strong> when slow-speed jog movement is required regardless of that signal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f02e2744\">The selected option must correspond to the machine manufacturer&#8217;s approved control configuration.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 4: Verify the Signal Status<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7cd4cb86\">If Close On is selected, qualified personnel should verify the Speed Change Signal using the controller&#8217;s available diagnostic functions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ad8a689a\">Confirm that the signal state corresponds to the expected operating condition.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 5: Test Jog Movement<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1a65ea0a\">After changing the parameter, perform a controlled operational test according to the machine manufacturer&#8217;s instructions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-61c6bbb5\">Observe the ram&#8217;s movement response and confirm that the selected speed logic operates as intended.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-af69db30\">Do not resume normal production until the machine&#8217;s movement behavior has been verified.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Close On vs. Close Off: Key Differences<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-244fb409\">The two configurations provide different methods of selecting jog movement speed.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Besonderheit<\/th><th>Close On<\/th><th>Close Off<\/th><\/tr><tr><td>Default Setting<\/td><td>Ja<\/td><td>NEIN<\/td><\/tr><tr><td>Speed Change Signal OFF<\/td><td>Fast movement<\/td><td>Slow movement<\/td><\/tr><tr><td>Speed Change Signal ON<\/td><td>Slow movement<\/td><td>Slow movement<\/td><\/tr><tr><td>Speed Selection<\/td><td>Signal-dependent<\/td><td>Fixed slow-speed selection<\/td><\/tr><tr><td>Main Function<\/td><td>Allows fast\/slow jog selection<\/td><td>Maintains slow jog speed<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-532a2060\">The ESTUN E315P Jog Mode therefore allows operators to select between signal-dependent speed control and continuous slow-speed selection.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4a817c4b\">The appropriate configuration depends on the machine&#8217;s intended operation and commissioning requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to Verify Jog Mode Operation<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ef84c719\">Verifying the ESTUN E315P Jog Mode requires checking both the parameter setting and the actual machine response.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Check the Selected Mode<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f94f869f\">Confirm that the Jog parameter matches the intended configuration.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-41743e04\">For Close On, the controller should select speed according to the Speed Change Signal.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2c2f7298\">For Close Off, the controller should select slow-speed movement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Check the Speed Change Signal<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-46dadf1a\">Use the available diagnostic or status-monitoring functions to inspect the signal where supported.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1395ca28\">Confirm that the displayed state corresponds to the machine&#8217;s expected signal condition.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Observe Ram Movement<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f3e4e600\">During an approved operational test, verify that the ram responds according to the selected mode.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2c9863a9\">Do not attempt to force a signal transition or modify safety wiring to test the speed selection.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Investigate Unexpected Behavior<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d81ea685\">If the ram moves at an unexpected speed, stop testing and investigate the relevant configuration, input signals, and machine conditions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-12bfdcfb\">The issue should not automatically be attributed to the Jog parameter alone.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Jog Mode vs. Normal Bending Operation<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8b6473b5\">The ESTUN E315P Jog Mode should not be confused with the complete automatic bending sequence.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-526367ca\">During normal bending, the controller manages several operating stages, including fast closing, pressing, dwell, decompression, and opening.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f8a426bf\">These stages involve their own operating conditions and control logic.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f8f74e48\">By comparison, the Jog parameter specifically determines speed selection during jog movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4f08fb1c\">Changing Jog does not directly adjust bending angle, pressure-holding duration, or the programmed lower dead point position.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-79857fd8\">Operators should identify the relevant operating function before modifying controller parameters.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Jog Mode Configuration Mistakes<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-90a4c5c6\">Several mistakes should be avoided when configuring the ESTUN E315P Jog Mode.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Confusing Close On with Slow-Speed Operation<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-37043dd8\">Close On does not mean that the ram always moves slowly.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3f25d2a7\">Under this setting, the Speed Change Signal determines whether fast or slow movement is selected.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Assuming Close Off Stops Ram Movement<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9956b80b\">Close Off does not disable jog movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-62bc0285\">It selects slow-speed operation rather than switching between fast and slow speeds.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ignoring Signal Conditions<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d1c1a93a\">When Close On is selected, an unexpected Speed Change Signal state may result in a different speed selection than anticipated.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f4f1ad08\">Qualified personnel should verify the relevant signal before troubleshooting unrelated parameters.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Changing Settings Without Testing<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-31549317\">A parameter change should always be followed by appropriate verification of the actual ram movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-212eb692\">Do not assume that the displayed setting alone confirms correct machine operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Practical Recommendations for Jog Mode Configuration<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-138ae97a\">Before modifying the ESTUN E315P Jog Mode, review the machine&#8217;s operating requirements and existing controller configuration.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2468be37\">Confirm whether signal-dependent speed selection or consistent slow-speed movement is required.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8395083a\">Record the original parameter value and verify the relevant input signal when using Close On.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f776acca\">After changing the setting, test the ram&#8217;s movement under controlled conditions and confirm that the machine responds as intended.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39fd2920\">Avoid changing unrelated speed parameters or electrical connections without a clear technical reason.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3d334fd7\">If unexpected movement occurs, stop operation and investigate the cause before continuing.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fb64ca8b\">Proper configuration of the ESTUN E315P Jog Mode helps operators maintain consistent jog movement behavior and supports reliable press brake operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions\uff08FAQ\uff09<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-1794464441991\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What Is the Difference Between Close On and Close Off?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Close On allows the Speed Change Signal to determine jog movement speed. When the signal is OFF, the controller selects fast movement; when it is ON, slow movement is selected. Close Off maintains slow-speed jog movement regardless of the signal state.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1794464452611\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Does Close Off Completely Disable Jog Movement?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>No. Close Off does not disable the jog function. It selects slow-speed movement instead of allowing the Speed Change Signal to switch between fast and slow speeds. The actual movement remains subject to the machine&#8217;s operating conditions and safety requirements.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Abschluss<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-519db4c2\">The ESTUN E315P Jog Mode is an important system parameter that determines how the <a href=\"https:\/\/www.youtube.com\/watch?v=AuW8tDyz14M\" data-type=\"link\" data-id=\"https:\/\/www.youtube.com\/watch?v=AuW8tDyz14M\" target=\"_blank\" rel=\"noopener\">Abkantpresse<\/a> controller selects ram movement speed during jog operation. According to the ESTUN E315P operating manual, the default setting is Close On, with Close On and Close Off available as configuration options.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d8283f1d\">When Close On is selected, the controller uses the Speed Change Signal to switch between fast and slow movement. When Close Off is selected, the ram operates at slow speed regardless of the signal state.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dbef5e2e\">Understanding these differences helps operators select the appropriate jog configuration and avoid confusion when troubleshooting unexpected ram movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a08046ab\">Before adjusting the ESTUN E315P Jog Mode, operators should record the existing setting, verify relevant signals, and follow the manufacturer&#8217;s approved testing procedures.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ba09c2e5\">Proper configuration and verification support consistent jog movement, reliable machine operation, and safer press brake commissioning.<\/p>","protected":false},"excerpt":{"rendered":"<p>What Is ESTUN E315P Jog Mode? Parameter Specification Parameter Name Jog Default Value Close On Available Options Close On \/<\/p>","protected":false},"author":32,"featured_media":92454,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[3249],"doc_tag":[5631,6243,6245],"knowledge_base":[3228],"class_list":["post-92356","docs","type-docs","status-publish","has-post-thumbnail","hentry","doc_category-system-operation","doc_tag-e315p-press-brake-controller","doc_tag-jog-mode","doc_tag-ram-movement-control","knowledge_base-press-brake"],"year_month":"2026-11","word_count":1447,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Christina","author_nicename":"christina","author_url":"https:\/\/www.harsle.com\/de\/author\/christina\/"},"doc_category_info":[{"term_name":"System Operation","term_url":"https:\/\/www.harsle.com\/de\/docs\/hydraulic-press\/system-operation\/"}],"doc_tag_info":[{"term_name":"E315P press brake controller","term_url":"https:\/\/www.harsle.com\/de\/docs-tag\/e315p-press-brake-controller\/"},{"term_name":"Jog Mode","term_url":"https:\/\/www.harsle.com\/de\/docs-tag\/jog-mode\/"},{"term_name":"Ram Movement Control","term_url":"https:\/\/www.harsle.com\/de\/docs-tag\/ram-movement-control\/"}],"jetpack_sharing_enabled":true,"knowledge_base_info":[{"term_name":"Press Brake","term_url":"https:\/\/www.harsle.com\/de\/docs\/press-brake\/","term_slug":"press-brake"}],"knowledge_base_slug":["press-brake"],"_links":{"self":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/docs\/92356","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/comments?post=92356"}],"version-history":[{"count":1,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/docs\/92356\/revisions"}],"predecessor-version":[{"id":92457,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/docs\/92356\/revisions\/92457"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/media\/92454"}],"wp:attachment":[{"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/media?parent=92356"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/doc_category?post=92356"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/doc_tag?post=92356"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/www.harsle.com\/de\/wp-json\/wp\/v2\/knowledge_base?post=92356"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}