{"id":91228,"date":"2026-10-26T07:50:29","date_gmt":"2026-10-26T07:50:29","guid":{"rendered":"https:\/\/www.harsle.com\/?post_type=docs&#038;p=91228"},"modified":"2026-10-26T07:50:32","modified_gmt":"2026-10-26T07:50:32","password":"","slug":"estun-e315p-decompression-time-settings","status":"publish","type":"docs","link":"https:\/\/www.harsle.com\/es\/docs\/estun-e315p-decompression-time-settings\/","title":{"rendered":"How to Adjust ESTUN E315P Decompression Time Correctly?"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-4ed83281\">Proper pressure release is an important part of the hydraulic press brake bending cycle. After the machine completes the pressing and dwell stages, hydraulic pressure must be released before the ram proceeds to the opening stage.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7d71d706\">The ESTUN E315P Decompression Time parameter controls the duration assigned to this pressure-release process. Correct configuration helps maintain an appropriate transition between bending operations and supports consistent machine operation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-27eb3200\">This guide explains the function of Decompression Time, its position within the bending sequence, how to adjust the parameter, and the precautions operators should consider during commissioning and production.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is ESTUN E315P Decompression Time?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-3b9ca550\">The ESTUN E315P Decompression Time is a programming constant that determines the time allocated to releasing bending pressure after the pressing and dwell stages.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-39e33b33\">According to the ESTUN E315P operating manual, the parameter is identified as <strong>Decomp Time<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Par\u00e1metro<\/th><th>Especificaci\u00f3n<\/th><\/tr><tr><td>Parameter Name<\/td><td>Decomp Time<\/td><\/tr><tr><td>Default Value<\/td><td>0.20 s<\/td><\/tr><tr><td>Setting Range<\/td><td>0.00\u201399.99 s<\/td><\/tr><tr><td>Unidad<\/td><td>Seconds (s)<\/td><\/tr><tr><td>Funci\u00f3n<\/td><td>Sets the decompression duration after pressing and dwell<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-29bb21bf\">The default value is 0.20 seconds. However, this is a controller default rather than a universally suitable setting for every hydraulic press brake.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-006e37ef\">The appropriate value should be determined according to the machine&#8217;s hydraulic configuration and actual operating conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does Decompression Work During Bending?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6723ac87\">To understand the ESTUN E315P Decompression Time, it is necessary to identify where decompression occurs within the bending cycle.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a1096445\">The E315P operating sequence includes several stages:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1. Fast Closing<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7dbbe333\">The ram moves downward toward the workpiece during the fast-closing stage.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Pressing<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c3ddb5d5\">The machine enters the working stroke and applies the force required for bending.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Dwell<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dd02341b\">The controller maintains the programmed dwell stage after pressing.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e3c88db3\">This stage is associated with the holding period during the bending operation.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Decompression<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6c5d5697\">After the pressing and dwell stages, the controller enters the decompression stage.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-616dc712\">The Decomp Time parameter specifies the duration allocated to releasing bending pressure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">5. Opening<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7eec9b81\">Following decompression, the ram proceeds to the opening stage according to the machine&#8217;s configured operating sequence.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7d1b1677\">Understanding this order helps operators distinguish pressure release from other timing functions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How to Adjust ESTUN E315P Decompression Time<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-72501621\">The adjustment should be performed carefully, particularly when the machine is being commissioned or its operating parameters are being reviewed.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"800\" src=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-1200x800.png\" alt=\"ESTUN E315P Decompression Time\" class=\"wp-image-91259\" srcset=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-1200x800.png 1200w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-400x267.png 400w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-768x512.png 768w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-18x12.png 18w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-360x240.png 360w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-430x287.png 430w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-700x467.png 700w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357-150x100.png 150w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/ESTUN-E315P-\u6298\u5f2f\u673a\u51cf\u538b\u65f6\u95f4\u53c2\u6570\u6307\u5357.png 1536w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Step 1: Access the Programming Constants<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cc314fb6\">Open the controller&#8217;s parameter settings and locate the <strong>C.1 Constants<\/strong> section described in the operating manual.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-02579947\">Find the parameter labeled <strong>Decomp Time<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 2: Check the Current Value<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-00e52d23\">Review the existing decompression setting before making any changes.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-414abdd2\">The factory default listed in the manual is 0.20 seconds.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-038cc3d2\">If the machine has already been commissioned successfully, record the existing value so it can be restored if necessary.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 3: Enter the Required Decompression Time<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6adec375\">Adjust the parameter within the permitted range of 0.00\u201399.99 seconds.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f88cf940\">Avoid selecting a value solely because it falls within the allowable range. The controller&#8217;s permitted range does not establish that every value is suitable for the machine.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Step 4: Verify the Bending Sequence<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f1e637a9\">After adjusting the ESTUN E315P Decompression Time, perform a controlled test using appropriate operating procedures.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-faea5927\">Observe the transition from dwell to decompression and then to opening.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d7bd990c\">Confirm that the machine completes the sequence normally before resuming regular production.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does Decompression Time Affect the Bending Cycle?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-25f3a9f0\">Decompression Time is one of the timing parameters involved in the complete bending sequence.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eeaecfd3\">Changing its value changes the programmed duration of the decompression stage.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0211a59c\">A longer setting allocates more time to pressure release, while a shorter setting reduces the time assigned to this stage.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-87e15a13\">However, the actual hydraulic response depends on the machine&#8217;s hydraulic system, valve configuration, and operating conditions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-05453afd\">Therefore, the ESTUN E315P Decompression Time should not be treated as an independent adjustment for bending force, bending angle, or hydraulic pressure.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e50120f5\">Its primary purpose is to define the decompression interval within the programmed operating cycle.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Decompression Time vs. Dwell Time<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-720caf88\">Although both parameters are measured in seconds, they serve different functions.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Par\u00e1metro<\/th><th>Funci\u00f3n<\/th><th>Operating Stage<\/th><\/tr><tr><td>Tiempo de permanencia<\/td><td>Determines the programmed holding period<\/td><td>After pressing<\/td><\/tr><tr><td>Decomp Time<\/td><td>Determines the pressure-release duration<\/td><td>After dwell, before opening<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-24816654\">The E315P manual lists a separate <strong>Tiempo de permanencia predeterminado<\/strong> parameter with a default value of 3 seconds and a setting range of 0.00\u201399.00 seconds.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b8d597ae\">By comparison, Decomp Time has a default value of 0.20 seconds.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-953be26b\">Operators should not confuse these settings when adjusting the bending sequence.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1f559ec6\">Increasing Dwell Time extends the programmed holding period, whereas increasing Decomp Time extends the programmed pressure-release interval.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Decompression Time Setting Mistakes<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-399af1f2\">When adjusting the ESTUN E315P Decompression Time, several mistakes should be avoided.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Confusing Decompression with Dwell<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e6b570e9\">These functions occur at different stages of the bending cycle. Changing one parameter does not replace the function of the other.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Using the Same Value for Every Machine<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-73393fc6\">Different hydraulic configurations may require different operating settings.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c5f4e8f9\">A parameter suitable for one press brake should not automatically be applied to another machine.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Making Large Adjustments Without Verification<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-14388cc6\">Significant timing changes should not be introduced without checking the resulting machine operation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7ee4cdbf\">Use the machine manufacturer&#8217;s commissioning requirements when determining an appropriate setting.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ignoring Abnormal Hydraulic Behavior<\/h3>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d5aecb33\">If the machine exhibits unusual pressure-release behavior, abnormal noise, unexpected ram movement, or hydraulic alarms, stop testing and investigate the underlying condition.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4a320fa9\">Changing Decomp Time alone should not be considered a solution to every hydraulic problem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Practical Recommendations for Safe Adjustment<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b7163e33\">Before modifying the ESTUN E315P Decompression Time, ensure that the machine is in a safe condition and that the adjustment is performed by authorized personnel.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5c044b3d\">Record the original setting and confirm the intended bending program.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8e6689f4\">After making an adjustment, observe a complete bending cycle and verify the transition between dwell, decompression, and opening.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-afdd7c01\">Do not attempt to compensate for suspected hydraulic faults by repeatedly increasing or decreasing the decompression interval.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-31c5e9fe\">For machines that have already been commissioned and operate normally, unnecessary parameter changes should be avoided.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9062f24c\">Correct use of the ESTUN E315P Decompression Time helps maintain a properly configured pressure-release stage and supports consistent press brake operation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Preguntas frecuentes<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-1792744100109\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Can Decompression Time Be Set to Zero?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Yes. The permitted setting range is 0.00\u201399.99 seconds, so zero is an available parameter value. However, the manual does not establish that zero is suitable for every machine. Operators should follow the machine manufacturer&#8217;s commissioning recommendations before using this setting.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1792744112679\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Does Decompression Time Control Hydraulic Pressure?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>No. Decompression Time specifies the duration of the pressure-release stage. It does not directly set hydraulic pressure or bending force. These functions depend on other machine parameters and hydraulic components.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1792744124873\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What Should Operators Check After Changing Decompression Time?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>After adjusting the ESTUN E315P Decompression Time, operators should verify that the bending cycle completes normally, the transition from dwell to opening is appropriate, and no abnormal hydraulic behavior or alarms occur. The original parameter value should be retained for reference.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Conclusi\u00f3n<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c77a2ae4\">El <a href=\"https:\/\/www.youtube.com\/watch?v=GwlCHLs7I6U\" data-type=\"link\" data-id=\"https:\/\/www.youtube.com\/watch?v=GwlCHLs7I6U\" target=\"_blank\" rel=\"noopener\">ESTUN E315P<\/a> Decompression Time is an important timing parameter that controls the pressure-release interval between the dwell and opening stages of a hydraulic press brake&#8217;s bending cycle.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-23161881\">According to the E315P operating manual, its default value is 0.20 seconds, with an adjustable range of 0.00\u201399.99 seconds. Although the controller allows a wide setting range, the appropriate value depends on the machine&#8217;s hydraulic configuration and operating conditions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9200a1ed\">Operators should distinguish decompression from dwell, record existing settings before making adjustments, and verify the complete bending sequence after any modification.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-347b7c35\">By configuring the ESTUN E315P Decompression Time correctly and following appropriate commissioning procedures, operators can maintain a consistent pressure-release sequence while avoiding unnecessary changes to established machine settings.<\/p>","protected":false},"excerpt":{"rendered":"<p>What Is ESTUN E315P Decompression Time? Parameter Specification Parameter Name Decomp Time Default Value 0.20 s Setting Range 0.00\u201399.99 s<\/p>","protected":false},"author":32,"featured_media":91257,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[3249],"doc_tag":[6178,5631,3347],"knowledge_base":[3228],"class_list":["post-91228","docs","type-docs","status-publish","has-post-thumbnail","hentry","doc_category-system-operation","doc_tag-decompression-time","doc_tag-e315p-press-brake-controller","doc_tag-press-brake-settings","knowledge_base-press-brake"],"year_month":"2026-11","word_count":1223,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Cristina","author_nicename":"christina","author_url":"https:\/\/www.harsle.com\/es\/author\/christina\/"},"doc_category_info":[{"term_name":"System Operation","term_url":"https:\/\/www.harsle.com\/es\/docs\/hydraulic-press\/system-operation\/"}],"doc_tag_info":[{"term_name":"Decompression Time","term_url":"https:\/\/www.harsle.com\/es\/docs-tag\/decompression-time\/"},{"term_name":"E315P press brake controller","term_url":"https:\/\/www.harsle.com\/es\/docs-tag\/e315p-press-brake-controller\/"},{"term_name":"Press Brake Settings","term_url":"https:\/\/www.harsle.com\/es\/docs-tag\/press-brake-settings\/"}],"jetpack_sharing_enabled":true,"knowledge_base_info":[{"term_name":"Press Brake","term_url":"https:\/\/www.harsle.com\/es\/docs\/press-brake\/","term_slug":"press-brake"}],"knowledge_base_slug":["press-brake"],"_links":{"self":[{"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/docs\/91228","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/comments?post=91228"}],"version-history":[{"count":0,"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/docs\/91228\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/media\/91257"}],"wp:attachment":[{"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/media?parent=91228"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/doc_category?post=91228"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/doc_tag?post=91228"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/www.harsle.com\/es\/wp-json\/wp\/v2\/knowledge_base?post=91228"}],"curies":[{"name":"gracias","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}