Le Recherche de tension globale shows the electricity supply in 172 countries: single-phase and three-phase voltage, frequency and plug types. Industrial machines run on the three-phase supply — for example 400 V 50 Hz in most of Europe, 380 V 50 Hz in China and 480 V or 208 V 60 Hz in the United States — so check it before you order a press brake, laser or shear.

  • Free, no sign-up
  • Instant results
  • Shareable link

Enter your values

Type the first letters to jump to a country.

Résultats

Live
Industrial supply (three-phase)208 / 480 V · 60 Hzthree-phase industrial supply in United States
Single-phase voltage
120 V
Three-phase voltage
208 / 480 V
Fréquence
60 Hz
Plug types
Type A, B
Specify on your machine order
3-phase 208 V or 480 V, 60 Hz

Several voltages are in use. Ask your electrician for the voltage at the machine location before ordering.

Nominal national values. Factories may have a different transformer voltage (e.g. 415, 440, 460 or 690 V) — always confirm on site.

Why the voltage matters when buying a machine

Motors, hydraulic pumps, servo drives, laser sources and control transformers are built for a specific supply. A machine wired for 400 V 50 Hz will run motors about 20% faster on 60 Hz, and a 230 V three-phase motor connected to 400 V will burn out. HARSLE builds every machine for the customer’s voltage and frequency, so please tell us:

  • Three-phase voltage between phases (e.g. 380, 400, 415, 440, 480 V)
  • Frequency (50 or 60 Hz)
  • Whether a neutral conductor is available (3-phase 4-wire or 3-wire)

Utilisez le electrical parameter calculator to size the breaker and cable once you know the supply.

How to use the Global Voltage Finder

  1. Sélectionnez le country where the machine will be installed.
  2. Read the three-phase voltage and frequency.
  3. Confirm the voltage at the factory and put it on your purchase order.

Voltage and frequency by country

PaysRegionmonophasétriphaséFréquencePlug types
AfghanistanAsia220 V380 V50 HzC, F
BangladeshAsia220 V380 V50 HzA, C, D, G, K
BhoutanAsia230 V400 V50 HzC, D, F, G, M
BruneiAsia240 V415 V50 HzG
CambodgeAsia230 V400 V50 HzA, C, G
ChineAsia220 V380 V50 HzA, C, I
Hong KongAsia220 V380 V50 HzD, G
IndeAsia230 V400 V50 HzC, D, M
IndonésieAsia230 V400 V50 HzC, F
JapanAsia100 V200 V50 (east) / 60 (west) HzA, B
KazakhstanAsia220 V380 V50 HzC, F
KirghizistanAsia220 V380 V50 HzC, F
LaosAsia230 V400 V50 HzA, B, C, E, F
MacauAsia220 V380 V50 HzD, F, G
MalaisieAsia240 V415 V50 HzG
MaldivesAsia230 V400 V50 HzC, D, G, J, K, L
MongoliaAsia230 V400 V50 HzC, E
BirmanieAsia230 V400 V50 HzA, C, D, G, I
NépalAsia230 V400 V50 HzC, D, M
North KoreaAsia220 V380 V50 HzA, C
PakistanAsia230 V400 V50 HzC, D
PhilippinesAsia220 V380 V60 HzA, B, C
SingapourAsia230 V400 V50 HzG
Corée du SudAsia220 V380 V60 HzC, F
Sri LankaAsia230 V400 V50 HzD, G
TaïwanAsia110 V220 / 380 V60 HzA, B
TadjikistanAsia220 V380 V50 HzC, F
ThaïlandeAsia230 V400 V50 HzA, B, C, F, O
Timor-LesteAsia220 V380 V50 HzC, E, F, I
TurkménistanAsia220 V380 V50 HzB, C, F
OuzbékistanAsia220 V380 V50 HzC, F
VietnamAsia220 V380 V50 HzA, C, F
BahreïnMiddle East230 V400 V50 HzG
L'IranMiddle East230 V400 V50 HzC, F
IrakMiddle East230 V400 V50 HzC, D, G
IsraëlMiddle East230 V400 V50 HzC, H, M
JordanieMiddle East230 V400 V50 HzB, C, D, F, G, J
KoweitMiddle East240 V415 V50 HzC, G
LibanMiddle East230 V400 V50 HzA, B, C, D, G
OmanMiddle East240 V415 V50 HzC, G
PalestineMiddle East230 V400 V50 HzC, H
QatarMiddle East240 V415 V50 HzD, G
Arabie SaouditeMiddle East230 (127 legacy) V400 (220 legacy) V60 HzG
SyrieMiddle East220 V380 V50 HzC, E, L
TurquieMiddle East230 V400 V50 HzC, F
United Arab EmiratesMiddle East230 V400 V50 HzC, D, G
YémenMiddle East230 V400 V50 HzA, D, G
AlbanieEurope230 V400 V50 HzC, F
ArménieEurope230 V400 V50 HzC, F
AustriaEurope230 V400 V50 HzC, F
AzerbaïdjanEurope220 V380 V50 HzC, F
BiélorussieEurope230 V400 V50 HzC, F
BelgiqueEurope230 V400 V50 HzC, E
Bosnia and HerzegovinaEurope230 V400 V50 HzC, F
BulgarieEurope230 V400 V50 HzC, F
CroatieEurope230 V400 V50 HzC, F
ChypreEurope230 V400 V50 HzG
République tchèqueEurope230 V400 V50 HzC, E
DanemarkEurope230 V400 V50 HzC, E, F, K
EstonieEurope230 V400 V50 HzC, F
FinlandeEurope230 V400 V50 HzC, F
FranceEurope230 V400 V50 HzC, E
GéorgieEurope220 V380 V50 HzC, F
AllemagneEurope230 V400 V50 HzC, F
GrèceEurope230 V400 V50 HzC, F
HongrieEurope230 V400 V50 HzC, F
IcelandEurope230 V400 V50 HzC, F
IrlandeEurope230 V400 V50 HzG
ItalieEurope230 V400 V50 HzC, F, L
KosovoEurope230 V400 V50 HzC, F
LettonieEurope230 V400 V50 HzC, F
LituanieEurope230 V400 V50 HzC, F
LuxembourgEurope230 V400 V50 HzC, F
MaltaEurope230 V400 V50 HzG
MoldavieEurope230 V400 V50 HzC, F
MonténégroEurope230 V400 V50 HzC, F
Pays-BasEurope230 V400 V50 HzC, F
North MacedoniaEurope230 V400 V50 HzC, F
NorvègeEurope230 V400 (some 230 IT) V50 HzC, F
PologneEurope230 V400 V50 HzC, E
PortugalEurope230 V400 V50 HzC, F
RoumanieEurope230 V400 V50 HzC, F
RussieEurope230 V400 V50 HzC, F
SerbieEurope230 V400 V50 HzC, F
SlovaquieEurope230 V400 V50 HzC, E
SlovénieEurope230 V400 V50 HzC, F
EspagneEurope230 V400 V50 HzC, F
SuèdeEurope230 V400 V50 HzC, F
SuisseEurope230 V400 V50 HzC, J
UkraineEurope230 V400 V50 HzC, F
United KingdomEurope230 V400 V50 HzG
AlgérieAfrica230 V400 V50 HzC, F
AngolaAfrica220 V380 V50 HzC
BéninAfrica220 V380 V50 HzC, E
BotswanaAfrica230 V400 V50 HzD, G, M
Burkina FasoAfrica220 V380 V50 HzC, E
BurundiAfrica220 V380 V50 HzC, E
CamerounAfrica220 V380 V50 HzC, E
TchadAfrica220 V380 V50 HzC, D, E, F
Congo (DRC)Africa220 V380 V50 HzC, D, E
Congo (Republic)Africa230 V400 V50 HzC, E
Côte d’IvoireAfrica220 V380 V50 HzC, E
DjiboutiAfrica220 V380 V50 HzC, E
EgypteAfrica220 V380 V50 HzC, F
ÉrythréeAfrica230 V400 V50 HzC, L
EthiopieAfrica220 V380 V50 HzC, E, F, L
GabonAfrica220 V380 V50 HzC
GhanaAfrica230 V400 V50 HzD, G
GuinéeAfrica220 V380 V50 HzC, F, K
KenyaAfrica240 V415 V50 HzG
LibériaAfrica120 V208 V60 HzA, B
LibyeAfrica230 V400 V50 HzC, L
MadagascarAfrica220 V380 V50 HzC, D, E, J, K
MalawiAfrica230 V400 V50 HzG
MaliAfrica220 V380 V50 HzC, E
MauritaniaAfrica220 V380 V50 HzC
MauritiusAfrica230 V400 V50 HzC, G
MarocAfrica220 V380 V50 HzC, E
MozambiqueAfrica220 V380 V50 HzC, F, M
NamibiaAfrica220 V380 V50 HzD, M
NigerAfrica220 V380 V50 HzA, B, C, D, E, F
NigeriaAfrica230 V415 V50 HzD, G
RwandaAfrica230 V400 V50 HzC, J
SénégalAfrica230 V400 V50 HzC, D, E, K
Sierra LeoneAfrica230 V400 V50 HzD, G
SomaliaAfrica220 V380 V50 HzC
Afrique du SudAfrica230 V400 V50 HzC, D, M, N
South SudanAfrica230 V400 V50 HzC, D
SoudanAfrica230 V400 V50 HzC, D
TanzanieAfrica230 V400 V50 HzD, G
AllerAfrica220 V380 V50 HzC
TunisieAfrica230 V400 V50 HzC, E
OugandaAfrica240 V415 V50 HzG
ZambieAfrica230 V400 V50 HzC, D, G
ZimbabweAfrica240 V415 V50 HzD, G
BahamasNorth America120 V208 V60 HzA, B
BarbadosNorth America115 V200 V50 HzA, B
BelizeNorth America110 / 220 V190 / 380 V60 HzA, B, G
CanadaNorth America120 V208 / 600 V60 HzA, B
Costa RicaNorth America120 V240 V60 HzA, B
CubaNorth America110 / 220 V190 / 440 V60 HzA, B, C, L
Dominican RepublicNorth America120 V208 V60 HzA, B
Le SalvadorNorth America120 V200 V60 HzA, B
GuatemalaNorth America120 V208 V60 HzA, B
HaitiNorth America110 V190 V60 HzA, B
HondurasNorth America120 V208 V60 HzA, B
JamaicaNorth America110 V190 V50 HzA, B
MexiqueNorth America127 V220 / 480 V60 HzA, B
NicaraguaNorth America120 V208 V60 HzA, B
PanamaNorth America120 V208 / 480 V60 HzA, B
Porto RicoNorth America120 V208 / 480 V60 HzA, B
Trinidad and TobagoNorth America115 V230 / 400 V60 HzA, B
États-UnisNorth America120 V208 / 480 V60 HzA, B
ArgentineSouth America220 V380 V50 HzC, I
BolivieSouth America230 V400 V50 HzA, C
BrésilSouth America127 / 220 V220 / 380 V60 HzC, N
ChiliSouth America220 V380 V50 HzC, L
ColombieSouth America120 V208 / 440 V60 HzA, B
ÉquateurSouth America120 V208 V60 HzA, B
ParaguaySouth America220 V380 V50 HzC
PérouSouth America220 V220 / 380 V60 HzA, B, C
SurinameSouth America127 / 230 V220 / 400 V60 HzC, F
UruguaySouth America230 V400 V50 HzC, F, L
VenezuelaSouth America120 V208 / 480 V60 HzA, B
AustralieOceania230 V400 V50 HzI
FidjiOceania240 V415 V50 HzI
Nouvelle-ZélandeOceania230 V400 V50 HzI
Papua New GuineaOceania240 V415 V50 HzI
SamoaOceania230 V400 V50 HzI
Solomon IslandsOceania230 V415 V50 HzG, I
TongaOceania240 V415 V50 HzI
VanuatuOceania230 V400 V50 HzC, G, I

Frequently asked questions

Which countries use 60 Hz?

Most of the Americas (United States, Canada, Mexico, Brazil, Colombia, Peru…), Saudi Arabia, South Korea, the Philippines, Taiwan, Liberia and western Japan. Nearly all other countries use 50 Hz.

What is the industrial voltage in Europe?

400 V three-phase, 50 Hz, with 230 V single-phase, across the EU, the UK and most neighbouring countries.

Can a 50 Hz machine run on 60 Hz?

Only if the motors, pumps and transformers are rated for it. Motors run about 20% faster on 60 Hz, which changes pump flow and fan speed. Order the machine for the local frequency.

What voltage does a press brake need?

Industrial press brakes, shears and lasers use the local three-phase supply, for example 380 V 50 Hz in China, 400 V 50 Hz in Europe or 480 V 60 Hz in the US. Single-phase machines are limited to very small sizes.

Reviewed by the HARSLE engineering team · Last updated October 2026. Results are engineering estimates; confirm critical values with your machine and tooling documentation.

Industrial supply (three-phase)—