{"id":90816,"date":"2026-10-14T06:45:54","date_gmt":"2026-10-14T06:45:54","guid":{"rendered":"https:\/\/www.harsle.com\/?post_type=docs&#038;p=90816"},"modified":"2026-10-14T06:45:58","modified_gmt":"2026-10-14T06:45:58","password":"","slug":"estun-e315p-maintenance-checks-guide","status":"publish","type":"docs","link":"https:\/\/www.harsle.com\/fr\/docs\/estun-e315p-maintenance-checks-guide\/","title":{"rendered":"How to Complete ESTUN E315P Maintenance Checks?"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-4c0e12d3\">Regular ESTUN E315P Maintenance Checks are essential for maintaining reliable controller operation and preventing electrical or mechanical problems during press brake operation. Proper maintenance involves inspecting the controller installation, electrical connections, environmental conditions, power supply, and related components.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2d5008ca\">According to the ESTUN E315P maintenance recommendations, inspections are divided into daily checks and periodic inspections. Daily checks focus on installation security, wiring connections, terminals, and display conditions. Periodic inspections cover additional electrical and environmental requirements.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5676cdcf\">This guide explains how to perform ESTUN E315P Maintenance Checks systematically, including important safety precautions, inspection procedures, and corrective actions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Are ESTUN E315P Maintenance Checks?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f2454737\">ESTUN E315P <a href=\"https:\/\/www.harsle.com\/fr\/docs\/press-brake-preventive-maintenance\/\" data-type=\"link\" data-id=\"https:\/\/www.harsle.com\/docs\/press-brake-preventive-maintenance\/\">Entretien<\/a> Checks are routine inspection procedures designed to verify that the CNC controller and its associated electrical components remain in suitable operating condition.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e76188e8\">The maintenance recommendations identify three main areas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Maintenance precautions<\/li>\n\n\n\n<li>Daily checks<\/li>\n\n\n\n<li>Periodic inspections<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aa7f70be\">Daily checks focus on components that should be inspected regularly, while periodic inspections provide a more comprehensive evaluation of the controller&#8217;s installation and operating environment.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f1fc0f85\">The recommended periodic inspection interval is every 6\u201312 months. Additional inspections are required when the device is relocated, its structure is modified, or the wiring system is changed.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d0f5d7cb\">Following these requirements helps technicians identify potential problems before they affect normal machine operation.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1200\" height=\"800\" src=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-1200x800.png\" alt=\"ESTUN E315P Maintenance Checks\" class=\"wp-image-90817\" srcset=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-1200x800.png 1200w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-400x267.png 400w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-768x512.png 768w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-18x12.png 18w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-360x240.png 360w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-430x287.png 430w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-700x467.png 700w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357-150x100.png 150w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/10\/\u5de5\u4e1a\u8bbe\u5907\u7ef4\u62a4\u68c0\u67e5\u6307\u5357.png 1536w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Step 1: Follow Maintenance Safety Precautions<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0c922b4f\">Before beginning ESTUN E315P Maintenance Checks, technicians must follow the electrical safety precautions specified in the manual.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e63f1619\">Do not open controller covers or panels while the power is on or while the system is operating. Wiring and inspection work should only be performed by qualified professionals.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ca8272d4\">Avoid touching integrated circuit pins or connector contacts directly, as improper handling may damage electronic components.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-47d4c512\">The controller should not be placed on conductive metal surfaces or materials prone to generating static electricity, such as wood, plastic, or vinyl.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2a38b269\">Additional precautions include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Verify programs and parameters before operation.<\/li>\n\n\n\n<li>Use only the specified supply voltage.<\/li>\n\n\n\n<li>Confirm correct power supply polarity.<\/li>\n\n\n\n<li>Keep control and communication cables more than 100 mm away from high-voltage power cables.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-273f5551\">Incorrect terminal wiring or reversed polarity may damage the controller&#8217;s electrical circuits.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-25cd3091\">If an alarm occurs, refer to Appendix D \u2013 Alarm Codes, identify and eliminate the fault, and confirm that the machine is safe before restarting.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 2: Perform Daily Installation Checks<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dd5920ec\">The first daily inspection item is the controller&#8217;s physical installation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bc1df636\">Check whether the mounting fasteners are secure and whether the installed components remain properly positioned.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d2e43f07\">Also inspect the integrity of the relevant seals.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f2187d0b\">The standard requirement is that the device must be securely installed.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bec52814\">If mounting screws or fasteners are loose, tighten them appropriately before continuing with normal operation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-74becbdf\">A secure installation helps prevent unwanted movement and maintains the intended mechanical mounting condition.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 3: Inspect I\/O Wiring and Terminal Connections<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-90a368a0\">Electrical connections are another important part of daily ESTUN E315P Maintenance Checks.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bc8f94b2\">Start by inspecting the I\/O port wiring.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e3299912\">Confirm that the connections are secure and that no wires have become loose.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-118117c4\">If a connection is loose, reconnect it correctly according to the machine&#8217;s electrical wiring requirements.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-54342d37\">Next, inspect the terminal connections.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6e3b7aaf\">The maintenance checklist requires technicians to check terminal screw tightness and confirm that no screws are loose.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-754da642\">If loose terminal screws are found, tighten them appropriately with the power safely isolated.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-0a5fd161\">These checks help maintain reliable electrical connections between the controller and the machine&#8217;s associated components.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 4: Check the Controller Display Status<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-db5330d0\">The daily inspection checklist also includes the controller display.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-973e4de9\">Verify that the display presents information correctly and that the visible status corresponds with the expected operating condition.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8366bf29\">Check whether the displayed information is readable and whether any obvious abnormalities are present.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7584c1c1\">If the display does not operate as expected, further inspection may be necessary to determine whether the issue is related to the controller, electrical supply, or another component.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eca7f067\">The objective of this inspection is to confirm normal display operation before the machine is used.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 5: Schedule Periodic Maintenance Inspections<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-34c187b7\">In addition to daily inspections, ESTUN E315P Maintenance Checks include periodic inspections.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-269c87a8\">The manual recommends performing these inspections every 6\u201312 months.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ce392284\">Additional inspections should also be carried out under the following conditions:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The device has been relocated or structurally modified.<\/li>\n\n\n\n<li>The wiring system has been altered.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cb73d323\">Periodic maintenance provides a more detailed inspection of the controller&#8217;s operating environment, supply voltage, installation, terminal connections, and relays.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6bdac5b1\">Technicians should follow the inspection requirements and corrective actions specified in the maintenance checklist.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 6: Check Environmental Conditions<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b9714325\">Environmental conditions can affect the reliability of electronic control equipment.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-efa5f32c\">During periodic maintenance, measure the ambient temperature and relative humidity using suitable instruments.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-94dafc5d\">The E315P maintenance checklist specifies the following requirements:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Inspection Item<\/th><th>Standard Requirement<\/th><\/tr><tr><td>Ambient Temperature<\/td><td>0\u201340\u00b0C<\/td><\/tr><tr><td>Relative Humidity<\/td><td>5\u201395% RH<\/td><\/tr><tr><td>Corrosive Gases<\/td><td>No corrosive gases<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a18fdd62\">Technicians should also inspect the surrounding environment for corrosive gases.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d769c8e5\">If the operating environment does not meet these requirements, the condition should be addressed before it affects the controller.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-91660a6c\">Maintaining the specified environmental conditions is an important part of long-term ESTUN E315P Maintenance Checks.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 7: Verify the Power Supply Voltage<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6477b349\">Le <a href=\"https:\/\/www.youtube.com\/watch?v=GwlCHLs7I6U&amp;t=246s\" data-type=\"link\" data-id=\"https:\/\/www.youtube.com\/watch?v=GwlCHLs7I6U&amp;t=246s\" target=\"_blank\" rel=\"noopener\">E315P<\/a> uses a nominal 24V DC power supply.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-731e1b64\">According to the periodic inspection checklist, the acceptable terminal voltage range is: <\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-63a28250\">20\u201329V DC<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-83df584f\">During inspection, measure the voltage at the relevant power terminals using suitable electrical measuring equipment.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c1f13a2d\">Compare the measured voltage with the specified range.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-29926b3c\">If the voltage is unstable or outside the permitted range, the manual recommends stabilizing or replacing the power supply.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cee52aa5\">Do not continue operating the controller with an unsuitable supply voltage, as incorrect electrical conditions may damage internal circuits.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-61590901\">Power supply verification should be performed by qualified personnel using appropriate electrical safety procedures.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 8: Inspect Installation and Module Security<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1fb74e20\">Periodic ESTUN E315P Maintenance Checks also include a detailed installation inspection.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-06400ece\">Check the tightness of mounting fasteners and verify that modules remain securely installed.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-37944f27\">The maintenance checklist requires modules to be firmly seated to prevent displacement caused by vibration.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8e075806\">If any module or mounting screw is loose, secure it appropriately.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-faa76317\">Technicians should also inspect the controller for dust or foreign substances.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4edbd9b5\">If contamination is present, remove it using a suitable cleaning method with the equipment safely isolated.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-046fb610\">Keeping the installation secure and free from contamination helps maintain suitable operating conditions for the controller.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 9: Inspect Terminal and Crimp Connections<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-42514388\">Terminal connections require additional attention during periodic maintenance.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-df186ddd\">Inspect the tightness of terminal screws and confirm that no connections have become loose.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8df49eb3\">The checklist also identifies the condition of crimp terminals and the spacing between connections.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7e20f819\">Crimped terminals should be securely installed with appropriate spacing between connections.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-adbca2e1\">If the terminal arrangement is incorrect, adjust the connections according to the required electrical installation standards.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e072f22f\">Check the tightness of the relevant joints and secure any loose connections.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-47e4fde5\">These procedures help prevent unreliable electrical contact and wiring-related faults.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 10: Check Relay Conditions<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c96774f9\">Relay inspection is included in the periodic maintenance checklist.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-1191e568\">Technicians should verify the relay contact condition and measure the coil resistance using a multimeter.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-85cab6de\">The measured resistance should remain within the applicable relay specifications.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-35822575\">The inspection also includes checking whether the relay contacts operate correctly.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-65c630b1\">If the relay does not meet the required conditions, the manual recommends replacing it.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-8368a515\">Because relay inspection involves electrical components, the procedure should be performed by qualified personnel using appropriate testing methods.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Final Maintenance Inspection Checklist<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f88389a2\">After completing the ESTUN E315P Maintenance Checks, review the inspection results before returning the controller to normal operation.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Inspection Category<\/th><th>Required Verification<\/th><\/tr><tr><td>S\u00e9curit\u00e9<\/td><td>Covers closed, wiring secure, correct polarity<\/td><\/tr><tr><td>Installation<\/td><td>Fasteners and modules securely installed<\/td><\/tr><tr><td>I\/O Wiring<\/td><td>Connections correctly wired and secure<\/td><\/tr><tr><td>Terminals<\/td><td>No loose screws or connections<\/td><\/tr><tr><td>Afficher<\/td><td>Normal display operation<\/td><\/tr><tr><td>Environnement<\/td><td>Temperature and humidity within limits<\/td><\/tr><tr><td>Alimentation \u00e9lectrique<\/td><td>24V DC nominal, 20\u201329V DC<\/td><\/tr><tr><td>Contamination<\/td><td>No dust or foreign substances<\/td><\/tr><tr><td>Relay<\/td><td>Correct contact condition and coil resistance<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fbca06cf\">If any inspection item fails to meet the specified requirements, complete the necessary corrective action before normal machine operation resumes.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c7d000a2\">Systematic ESTUN E315P Maintenance Checks help maintain electrical reliability, identify developing faults, and support the safe operation of the CNC controller over time.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions\uff08FAQ\uff09<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-1791957774854\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Can ESTUN E315P Maintenance Checks Be Performed While the Machine Is Running?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>No. Electrical wiring inspections, terminal tightening, and internal component checks must not be performed while the controller is energized or operating. Qualified personnel should isolate the power supply and verify that the equipment is safe before beginning maintenance. Any powered diagnostic measurements must follow appropriate electrical safety procedures.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1791957785222\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">How Can I Identify a Loose Terminal Connection?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Inspect the terminal screws and connected wires for visible looseness or movement. A loose connection may also contribute to intermittent electrical signals. During ESTUN E315P Maintenance Checks, terminal connections should be inspected with the power safely isolated, and loose screws should be tightened appropriately.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ec6da22e\">Regular ESTUN E315P Maintenance Checks help maintain reliable controller operation and identify potential electrical or installation problems before they affect press brake performance.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-17ce2a61\">Daily inspections should focus on mounting security, I\/O wiring, terminal connections, and display status. More comprehensive inspections should be performed every 6\u201312 months, as well as after equipment relocation, structural modifications, or wiring changes.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cbece8bc\">During periodic maintenance, technicians should verify environmental conditions, power supply voltage, module installation, terminal connections, and relay performance. All inspections must follow the manufacturer&#8217;s electrical safety precautions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e175de47\">By following a structured maintenance schedule and correcting abnormalities promptly, technicians can improve equipment reliability, reduce unexpected interruptions, and support the long-term operation of the E315P CNC controller.<\/p>","protected":false},"excerpt":{"rendered":"<p>What Are ESTUN E315P Maintenance Checks? Step 1: Follow Maintenance Safety Precautions Step 2: Perform Daily Installation Checks Step 3:<\/p>","protected":false},"author":32,"featured_media":90818,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[3249],"doc_tag":[4660,5631,6125],"knowledge_base":[3228],"class_list":["post-90816","docs","type-docs","status-publish","has-post-thumbnail","hentry","doc_category-system-operation","doc_tag-bending-machine-adjustment","doc_tag-e315p-press-brake-controller","doc_tag-preventive-maintenance-e315p-press-brake-controller","knowledge_base-press-brake"],"year_month":"2026-10","word_count":1541,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Christine","author_nicename":"christina","author_url":"https:\/\/www.harsle.com\/fr\/author\/christina\/"},"doc_category_info":[{"term_name":"System Operation","term_url":"https:\/\/www.harsle.com\/fr\/docs\/hydraulic-press\/system-operation\/"}],"doc_tag_info":[{"term_name":"Bending Machine Adjustment","term_url":"https:\/\/www.harsle.com\/fr\/docs-tag\/bending-machine-adjustment\/"},{"term_name":"E315P press brake controller","term_url":"https:\/\/www.harsle.com\/fr\/docs-tag\/e315p-press-brake-controller\/"},{"term_name":"Preventive Maintenance","term_url":"https:\/\/www.harsle.com\/fr\/docs-tag\/preventive-maintenance-e315p-press-brake-controller\/"}],"jetpack_sharing_enabled":true,"knowledge_base_info":[{"term_name":"Press Brake","term_url":"https:\/\/www.harsle.com\/fr\/docs\/press-brake\/","term_slug":"press-brake"}],"knowledge_base_slug":["press-brake"],"_links":{"self":[{"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/docs\/90816","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/comments?post=90816"}],"version-history":[{"count":2,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/docs\/90816\/revisions"}],"predecessor-version":[{"id":90820,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/docs\/90816\/revisions\/90820"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/media\/90818"}],"wp:attachment":[{"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/media?parent=90816"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/doc_category?post=90816"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/doc_tag?post=90816"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/www.harsle.com\/fr\/wp-json\/wp\/v2\/knowledge_base?post=90816"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}