{"id":93161,"date":"2026-11-26T08:41:56","date_gmt":"2026-11-26T08:41:56","guid":{"rendered":"https:\/\/www.harsle.com\/?post_type=docs&#038;p=93161"},"modified":"2026-11-26T08:42:00","modified_gmt":"2026-11-26T08:42:00","password":"","slug":"et18-machine-status-monitoring","status":"publish","type":"docs","link":"https:\/\/www.harsle.com\/pl\/docs\/et18-machine-status-monitoring\/","title":{"rendered":"How to Monitor ET18 Machine Status Efficiently?"},"content":{"rendered":"<p class=\"wp-block-wd-paragraph wd-cdf7f2c6\">ET18 Machine Status provides a centralized diagnostic interface for monitoring input signals, output signals, axis feedback, and historical alarms on electro-hydraulic press brakes. By reviewing these operating conditions, operators and maintenance personnel can identify abnormal machine behavior and investigate potential problems more efficiently.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-86ef0446\">Unlike programming interfaces, the machine status page focuses on system feedback and equipment diagnostics.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-530f1b19\">This guide explains how to access the status interface, interpret operating data, understand debugging functions, and review historical alarm records.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is ET18 Machine Status?<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e9465488\">ET18 Machine Status is a dedicated monitoring interface within the EASYCAT ET18 hydraulic bending control system.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-686c6ed1\">According to the operating manual, operators can observe system input and output signals on this page to analyze potential machine problems.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-453d6af9\">To access the interface, select the Status icon from the main navigation menu.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f1c8dfe3\">The machine status interface contains several functional areas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Input signal monitoring<\/li>\n\n\n\n<li>Output signal monitoring<\/li>\n\n\n\n<li>Equipment feedback<\/li>\n\n\n\n<li>Debugging functions<\/li>\n\n\n\n<li>Auxiliary axis information<\/li>\n\n\n\n<li>Historical alarm records<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"643\" height=\"364\" src=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/73b90d902f5b0f6b004e3d17c8ecd19c.png\" alt=\"ET18 Machine Status\" class=\"wp-image-93162\" srcset=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/73b90d902f5b0f6b004e3d17c8ecd19c.png 643w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/73b90d902f5b0f6b004e3d17c8ecd19c-400x226.png 400w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/73b90d902f5b0f6b004e3d17c8ecd19c-18x10.png 18w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/73b90d902f5b0f6b004e3d17c8ecd19c-360x204.png 360w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/73b90d902f5b0f6b004e3d17c8ecd19c-430x243.png 430w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/73b90d902f5b0f6b004e3d17c8ecd19c-150x85.png 150w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-f6331a52\">These areas provide different types of diagnostic information and help maintenance personnel understand the machine&#8217;s operating conditions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Monitoring Input Signals<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a6eb5388\">The Input section of the ET18 Machine Status interface displays signals associated with external switches, operating commands, and axis reference positions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cdf17918\">The manual screenshot includes the following input signals:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Input Signal<\/th><th>Opis<\/th><\/tr><tr><td>Pedal Up<\/td><td>Foot pedal upward command<\/td><\/tr><tr><td>Pedal Down<\/td><td>Foot pedal downward command<\/td><\/tr><tr><td>Oil Switch<\/td><td>Oil pump switch signal<\/td><\/tr><tr><td>Oil Feedback<\/td><td>Oil system feedback signal<\/td><\/tr><tr><td>Konserwacja<\/td><td>Maintenance-related signal<\/td><\/tr><tr><td>X Limit<\/td><td>X-axis limit signal<\/td><\/tr><tr><td>X Origin<\/td><td>X-axis reference origin signal<\/td><\/tr><tr><td>R Limit<\/td><td>R-axis limit signal<\/td><\/tr><tr><td>R Origin<\/td><td>R-axis reference origin signal<\/td><\/tr><tr><td>Z1 Origin<\/td><td>Z1-axis reference origin signal<\/td><\/tr><tr><td>Z2 Origin<\/td><td>Z2-axis reference origin signal<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-c2ab361e\">When investigating an operating problem, maintenance personnel can review the relevant input signal and determine whether the controller is receiving the expected feedback.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-22de5c41\">For example, if the machine does not respond to a foot pedal command, the corresponding input status can provide useful diagnostic information.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-27d9605c\">However, the displayed port number alone does not establish whether a signal is active.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Understanding Output Signal Monitoring<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ea7a4429\">The Output section displays signals associated with hydraulic valves and other machine functions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-117e7dcb\">The ET18 Machine Status interface includes the following output items:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Output Signal<\/th><th>Opis<\/th><\/tr><tr><td>Slow Down Valve<\/td><td>Slow downward movement valve<\/td><\/tr><tr><td>Quick Drop Valve<\/td><td>Rapid downward movement valve<\/td><\/tr><tr><td>Return Valve<\/td><td>Ram return valve<\/td><\/tr><tr><td>Oil Pump DO<\/td><td>Oil pump digital output<\/td><\/tr><tr><td>Punkt zaciskowy<\/td><td>Clamping-point-related output<\/td><\/tr><tr><td>Clearing of Fault<\/td><td>Fault reset output<\/td><\/tr><tr><td>LED<\/td><td>Lighting output<\/td><\/tr><tr><td>Deflection Increase<\/td><td>Crowning compensation increase<\/td><\/tr><tr><td>Deflection Reduction<\/td><td>Crowning compensation reduction<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-dccdbc06\">Monitoring these outputs helps maintenance personnel determine whether the controller is issuing the relevant commands.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-cf810655\">An active output does not necessarily confirm that the corresponding physical component is functioning correctly. Electrical connections, hydraulic components, and mechanical conditions may require further inspection.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Reviewing Equipment Feedback<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-9186bd8e\">The Equipment section provides additional operating data associated with the hydraulic system and machine axes.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-186264cc\">The displayed information includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Y1 and Y2 voltage values<\/li>\n\n\n\n<li>Main pressure control voltage<\/li>\n\n\n\n<li>Y1 and Y2 position feedback<\/li>\n\n\n\n<li>Y1 and Y2 movement velocity<\/li>\n\n\n\n<li>Z1 and Z2 grating feedback<\/li>\n\n\n\n<li>Hand pulse feedback<\/li>\n\n\n\n<li>X, R, Z1, and Z2 servo information<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5ab19eb7\">Position feedback is displayed in millimeters, while movement velocity is displayed in millimeters per second.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-7ee04d8d\">These values help maintenance personnel compare machine behavior with the expected operating conditions.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6c35890d\">For example, differences between Y1 and Y2 position feedback may require further investigation when abnormal ram synchronization is suspected.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-bb790521\">The displayed main pressure voltage should not be confused with an actual hydraulic pressure reading in MPa or bar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Understanding ET18 Debug Mode<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6b21397b\">The ET18 Machine Status page also provides a dedicated Debug Mode for technical commissioning and troubleshooting.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-edf22e69\">According to the manual, the debugging interface supports output control, proportional valve calibration, and manual ram movement.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-e77efadc\">Selecting Output in the debugging area displays the control status of the corresponding output ports.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a303c37c\">The interface also contains settings associated with Y1 Opening, Y2 Opening, and Main Pressure.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4f936a8b\">Additional functions include:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-db1df4d3\"><strong>Y1Y2 Clear:<\/strong> Clears the current Y1 and Y2 position feedback.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-feeb1ee1\"><strong>Y1Y2 Home:<\/strong> Provides a function for returning Y1 and Y2 to their reference origins.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2fe51d79\">Debugging functions can directly affect hydraulic outputs and ram movement. They should only be used by qualified technical personnel following the machine manufacturer&#8217;s approved commissioning procedures.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6818d283\">Operators should not activate forced outputs or clear position feedback during normal production.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"643\" height=\"364\" src=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/e1abcf53fa6e67aafb1457dfadaa799b.png\" alt=\"ET18 Machine Status\" class=\"wp-image-93163\" srcset=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/e1abcf53fa6e67aafb1457dfadaa799b.png 643w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/e1abcf53fa6e67aafb1457dfadaa799b-400x226.png 400w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/e1abcf53fa6e67aafb1457dfadaa799b-18x10.png 18w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/e1abcf53fa6e67aafb1457dfadaa799b-360x204.png 360w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/e1abcf53fa6e67aafb1457dfadaa799b-430x243.png 430w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/e1abcf53fa6e67aafb1457dfadaa799b-150x85.png 150w\" sizes=\"(max-width: 643px) 100vw, 643px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">How to Review Historical Alarm Records<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-6e107453\">Historical alarm records are another important feature of ET18 Machine Status.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a14cd9d5\">To access the alarm history, select the Alarm Logs button at the bottom of the status interface.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-fccee3fd\">The controller opens a historical alarm record window containing previously recorded alarm messages.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a0bd85d7\">The manual provides examples of the following alarms:<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-2717a362\"><strong>Comm with HMI timed out:<\/strong> Indicates a communication timeout involving the human-machine interface.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b3ccdec5\"><strong>Oil pump not on:<\/strong> Indicates that the oil pump is not in the required operating state.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-eb2d4836\"><strong>Locked:<\/strong> Indicates a locked condition requiring further investigation.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d682d73a\">These messages provide a starting point for troubleshooting but do not necessarily identify the underlying cause.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-ed2bc211\">The alarm history window also contains a Clear button. Before clearing historical records, maintenance personnel should save relevant alarm information for further analysis.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"401\" height=\"595\" src=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/8ded93ff1ad61b3771de79afdc547bee.png\" alt=\"ET18 Machine Status\" class=\"wp-image-93165\" srcset=\"https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/8ded93ff1ad61b3771de79afdc547bee.png 401w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/8ded93ff1ad61b3771de79afdc547bee-202x300.png 202w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/8ded93ff1ad61b3771de79afdc547bee-8x12.png 8w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/8ded93ff1ad61b3771de79afdc547bee-345x512.png 345w, https:\/\/www.harsle.com\/wp-content\/uploads\/2026\/11\/8ded93ff1ad61b3771de79afdc547bee-150x223.png 150w\" sizes=\"(max-width: 401px) 100vw, 401px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Practical Troubleshooting Recommendations<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-387bcc64\">When using ET18 Machine Status for troubleshooting, follow a structured diagnostic approach.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a3fe036d\">First, identify the abnormal machine behavior and review any available alarm records.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a587d31d\">Next, check the relevant input signals to determine whether the expected commands or feedback are present.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-5550ab3c\">Then, review the corresponding output signals and equipment feedback.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-083ce9b0\">If the controller indicates an expected output but the machine does not respond, further electrical, hydraulic, or mechanical inspection may be necessary.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-a3c6e62a\">Record the relevant status information before contacting technical support.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-69199b9c\">This approach helps narrow down potential problems without making unnecessary parameter adjustments.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions\uff08FAQ\uff09<\/h2>\n\n\n<div id=\"rank-math-faq\" class=\"rank-math-block\">\n<div class=\"rank-math-list\">\n<div id=\"faq-question-1795680451843\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Can ET18 Machine Status Help Diagnose Foot Pedal Problems?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>Yes. The input monitoring area displays Pedal Up and Pedal Down signals. Reviewing these signals can help determine whether the controller receives the corresponding foot pedal commands.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1795680459766\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">What Does \u201cComm with HMI Timed Out\u201d Mean?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>This alarm indicates a communication timeout involving the controller&#8217;s human-machine interface. The exact cause requires further diagnostic inspection.<\/p>\n\n<\/div>\n<\/div>\n<div id=\"faq-question-1795680467598\" class=\"rank-math-list-item\">\n<h3 class=\"rank-math-question\">Does Clearing Alarm Records Resolve Machine Faults?<\/h3>\n<div class=\"rank-math-answer\">\n\n<p>No. Clearing historical alarm records does not eliminate the underlying machine fault. The cause must be identified and corrected separately.<\/p>\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Wniosek<\/h2>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-d4534bbc\">ET18 Machine Status provides valuable diagnostic information for monitoring electro-hydraulic press brake operation. Its input and output monitoring functions, equipment feedback, debugging interface, and historical alarm records help maintenance personnel investigate potential machine problems.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-b471c876\">Understanding the relationship between controller commands and actual machine behavior is essential for effective troubleshooting.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-aa1c793b\">Operators should use the monitoring functions to collect accurate diagnostic information, while advanced debugging and calibration should remain the responsibility of qualified technical personnel.<\/p>\n\n\n\n<p class=\"wp-block-wd-paragraph wd-4bc7d31f\">By using <a href=\"https:\/\/www.youtube.com\/watch?v=yyx8Z6SqYFM\" data-type=\"link\" data-id=\"https:\/\/www.youtube.com\/watch?v=yyx8Z6SqYFM\" target=\"_blank\" rel=\"noopener\">ET18<\/a> Machine Status appropriately, manufacturers can improve troubleshooting efficiency, reduce unnecessary adjustments, and support reliable press brake operation.<\/p>","protected":false},"excerpt":{"rendered":"<p>What Is ET18 Machine Status? Monitoring Input Signals Input Signal Description Pedal Up Foot pedal upward command Pedal Down Foot<\/p>","protected":false},"author":32,"featured_media":93167,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[3249],"doc_tag":[5306,6266,6294],"knowledge_base":[3228],"class_list":["post-93161","docs","type-docs","status-publish","has-post-thumbnail","hentry","doc_category-system-operation","doc_tag-cnc-troubleshooting","doc_tag-et18","doc_tag-machine-status","knowledge_base-press-brake"],"year_month":"2026-11","word_count":1077,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Krystyna","author_nicename":"christina","author_url":"https:\/\/www.harsle.com\/pl\/author\/christina\/"},"doc_category_info":[{"term_name":"System Operation","term_url":"https:\/\/www.harsle.com\/pl\/docs\/hydraulic-press\/system-operation\/"}],"doc_tag_info":[{"term_name":"CNC troubleshooting","term_url":"https:\/\/www.harsle.com\/pl\/docs-tag\/cnc-troubleshooting\/"},{"term_name":"ET18","term_url":"https:\/\/www.harsle.com\/pl\/docs-tag\/et18\/"},{"term_name":"Machine Status","term_url":"https:\/\/www.harsle.com\/pl\/docs-tag\/machine-status\/"}],"jetpack_sharing_enabled":true,"knowledge_base_info":[{"term_name":"Press Brake","term_url":"https:\/\/www.harsle.com\/pl\/docs\/press-brake\/","term_slug":"press-brake"}],"knowledge_base_slug":["press-brake"],"_links":{"self":[{"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/docs\/93161","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/comments?post=93161"}],"version-history":[{"count":2,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/docs\/93161\/revisions"}],"predecessor-version":[{"id":93166,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/docs\/93161\/revisions\/93166"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/media\/93167"}],"wp:attachment":[{"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/media?parent=93161"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/doc_category?post=93161"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/doc_tag?post=93161"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/www.harsle.com\/pl\/wp-json\/wp\/v2\/knowledge_base?post=93161"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}