Liquid Cooling Cabinet Production Line | HARSLE Sheet Metal Manufacturing Solutions
Soluciones de fabricación HARSLE

Completo Gabinete de refrigeración líquida Línea de montaje

Turnkey Sheet Metal Line for CDU Enclosures, Rear-Door Heat Exchangers, Manifold Panels & AI Liquid-Cooled Racks

Corte por láser Punzonado CNC Doblado de paneles Leak-Test Ready High-Density AI

AI and hyperscale data centers are shifting to liquid cooling to manage GPU thermal loads beyond air-cooled limits. HARSLE designs complete manufacturing lines for liquid cooling cabinet OEMs — from chassis blanking and coolant-path cutouts through precision forming, welded manifolds, coating, and assembly — scaled to your cabinet depth, flow layout, and daily output.

Productos Vell
100kW+ Rack Thermal Class
±0,1 mm Laser Cut Accuracy
CDU / RDHx Enclosure Types
Llavero Ingeniería de línea

Why Liquid Cooling Cabinet Manufacturing Is Growing

GPU-dense AI clusters and next-generation data centers are redefining thermal design. These drivers shape modern liquid cooling enclosure production lines.

Expansión de los centros de datos de IA

AI Data Center Expansion

New AI-ready facilities deploy liquid-cooled racks at scale — driving demand for dedicated sheet metal lines that can produce chassis, manifolds, and CDU housings with repeatable precision.

Adopción de la refrigeración líquida

Adopción de la refrigeración líquida

Direct-to-chip, rear-door heat exchanger, and immersion cooling systems replace air-only designs — requiring new enclosure geometries, hose ports, and leak-test-ready weld quality.

Mayor densidad de racks

Higher Rack Density & Power

Modern GPU racks exceed 50–100 kW per cabinet. Stronger frames, deeper chassis, and integrated coolant distribution panels demand heavier-gauge forming and structural welding.

CDU and Facility Cooling Infrastructure

CDU & Facility Cooling Infrastructure

Coolant distribution units, pump skids, and manifold enclosures expand the product mix — manufactured on the same integrated line as server-side liquid cooling cabinets.

Liquid Cooling Cabinet Manufacturing Process

From raw sheet metal to a finished liquid cooling cabinet — chassis forming, coolant-path machining, welding, coating, and assembly in one integrated flow.

Liquid Cooling Cabinet Production Line
Paso 01 / 09
Flujo de fabricación

    Machines for Liquid Cooling Cabinet Lines

    Six machines arranged for liquid cooling cabinet lines — shearing and laser blanking first, CNC punch and panel bender for rack panels, then press brake, laser weld, and downstream coating support.

    Máquina de corte de guillotina
    Cizallamiento

    Máquina de corte de guillotina

    Serie HARSLE QC11Y / QC12Y

    Front-end of the liquid cooling line — shears carbon steel, stainless, and aluminum coils into flat blanks sized for laser cutting, punching, and forming stations downstream.

    Chassis Sheet to Line-Ready Blanks
    Bordes limpios · Mínima distorsión de la hoja
    Steady Feed for 1.0–3.0mm Rack & CDU Sheet
    Máquina de corte por láser de fibra
    Corte por láser

    Máquina de corte por láser de fibra

    Serie HARSLE EcoCut / ProCut

    Blanks liquid-cooled chassis sections, manifold plates, hose port panels, and RDHx door contours before forming — the precision step for coolant-path and mounting cutouts on every liquid cooling cabinet line.

    Coolant Port & Hose Gland Cutouts
    Manifold & RDHx Panel Contours
    Precisión de ±0,1 mm · Bajo desperdicio de material
    Punzonadora de torreta CNC
    Equipo básico

    Punzonadora de torreta CNC

    Serie de torretas servo HARSLE D-ES300

    The highest-volume station on a liquid cooling cabinet line — punches cage nut rails, GPU tray patterns, vent grids, and connector cutouts across thousands of identical chassis and side panels per shift.

    19″ / 21″ Rail & Tray Hole Patterns
    Manifold Cover Vents & Louver Forms
    Torreta de indexación automática · Precisión de ±0,05 mm
    Panel Bender for Liquid Cooling Cabinets
    Dobladora de paneles

    Panel Bender for Liquid Cooling Cabinets

    Serie HARSLE AutoBend

    Automatically forms rear-door heat exchanger housings, side plenum panels, and CDU covers in one pass — cutting labor and cycle time on standardized AI liquid-cooled rack models.

    RDHx Door & Plenum One-Pass Forming
    CDU Cover & Side Panel Production
    Consistent Flange Width for Gasket Seams
    Prensa plegadora CNC
    Prensa Plegadora

    Prensa plegadora CNC

    Serie MasterBend — DA69T / DA66T

    Complements the panel bender — forms deep liquid-cooling chassis uprights, CDU frame sections, manifold brackets, and load-bearing stiffeners that panel benders do not complete in one cycle.

    Deep Chassis Upright & Rail Bending
    CDU Frame & Manifold Bracket Forming
    Automatic Crowning for Long Rack Panels
    Máquina de soldadura láser
    Soldadura láser

    Máquina de soldadura láser

    Serie HARSLE SmartWeld

    Joins liquid cooling frames, manifold brackets, and fluid-path housings with clean, low-distortion seams — reducing grinding before coating and supporting leak-test-ready cabinet assemblies.

    Chassis Frame & Manifold Bracket Welding
    Costuras al ras · Menos trabajo posterior al rectificado
    Stainless & Mild Steel Rack Structures

    Productos que ayudamos a fabricar

    Liquid cooling enclosures and related sheet metal products produced on HARSLE manufacturing lines — built for AI data centers and hyperscale thermal infrastructure.

    Gabinete de refrigeración líquida
    01

    Gabinete de refrigeración líquida

    Gabinete para servidor GPU
    02

    Gabinete para servidor GPU

    Rack de servidores de IA
    03

    Rack de servidores de IA

    Gabinete para centro de datos
    04

    Gabinete para centro de datos

    CDU Enclosure
    05

    CDU Enclosure

    Rear-Door Heat Exchanger
    06

    Rear-Door Heat Exchanger

    Manifold & Plenum Panel
    07

    Manifold & Plenum Panel

    Sidecar Cooling Cabinet
    08

    Sidecar Cooling Cabinet

    ¿Por qué elegir HARSLE?

    Engineered for AI liquid cooling programs — precision chassis forming, coolant-path machining, and leak-critical weld quality.

    🎯

    Precision Chassis Manufacturing

    Corte de ±0,1 mm · Curvatura de ±0,1°

    Laser and CNC forming tuned for hose ports, manifold interfaces, and rack rail spacing on high-density liquid-cooled cabinets.

    💧

    Liquid Cooling Enclosure Know-How

    CDU · RDHx · Manifold

    Process parameters cover rear-door exchanger housings, CDU skids, and server-side cabinets on one integrated sheet metal line.

    🏭

    Ingeniería de líneas llave en mano

    Diseño · Equipamiento · Instalación

    From shearing and laser cutting through coating and assembly — one supplier plans, delivers, and commissions the full liquid cooling cabinet factory.

    🌍

    Red de servicios global

    Más de 100 países

    Worldwide installation, operator training, and spare parts support keep AI infrastructure and thermal OEM lines running without interruption.

    📐

    19″ / 21″ Rack Compatibility

    42U · Custom Depth · GPU Tray

    Equipment tuned for standard rack formats, deep liquid-cooled chassis depths, and customer-specific coolant routing layouts.

    ⚙️

    Capacidad multimaterial

    Acero · Acero inoxidable · Aluminio

    Process mild steel, stainless steel, and aluminum across cutting, punching, bending, welding, and coating on a single integrated line.

    Diseño de la línea de producción de muestra

    A reference layout for liquid cooling cabinet production — sheet preparation, laser cutting, CNC punching, forming, welding, coating, assembly, and final packing in one flow.

    Liquid Cooling Cabinet Production Flow
    01
    Almacenamiento y corte de láminas
    Line-ready chassis blanks
    02
    Corte por láser de fibra
    Chassis, ports, manifold panels
    03
    Punzonado de torreta CNC
    Rails, vents, connector cutouts
    06
    Área de soldadura láser
    Unión de marcos y soportes
    05
    Conformado con prensa plegadora
    Rieles, montantes, soportes
    04
    Doblado de paneles
    RDHx doors, CDU covers, plenums
    07
    Rectificado y recubrimiento
    Desbarbado y acabado en polvo
    08
    Ensamblaje de gabinetes y control de calidad
    Rails, ports, hose brackets
    09
    Embalaje de gabinetes terminados
    Export-ready liquid cooling cabinets
    01
    Almacenamiento y corte de láminas
    Line-ready chassis blanks
    02
    Corte por láser de fibra
    Chassis, ports, manifold panels
    03
    Punzonado de torreta CNC
    Rails, vents, connector cutouts
    04
    Doblado de paneles
    RDHx doors, CDU covers, plenums
    05
    Conformado con prensa plegadora
    Rieles, montantes, soportes
    06
    Área de soldadura láser
    Unión de marcos y soportes
    07
    Rectificado y recubrimiento
    Desbarbado y acabado en polvo
    08
    Ensamblaje de gabinetes y control de calidad
    Rails, ports, hose brackets
    09
    Embalaje de gabinetes terminados
    Export-ready liquid cooling cabinets

    Centro de vídeo

    See HARSLE equipment processing liquid cooling chassis panels, manifold plates, and structural frames in live factory conditions.

    Prensa plegadora HARSLE Genius

    MasterBend press brake forming deep liquid cooling chassis uprights and mounting rails for AI server enclosures.

    Panel Bender — RDHx & Plenum Panels

    Automatic panel bender completing rear-door heat exchanger housings and plenum covers in a single pass — ideal for liquid cooling batch runs.

    Laser Cutting — Chassis & Manifold Panels

    Fiber laser cutting liquid cooling chassis blanks, hose port panels, and manifold plates at full speed on a production line floor.

    Preguntas frecuentes

    HARSLE machines support Carbon Steel, Stainless Steel, and Aluminum — the three primary materials used in liquid cooling cabinet, CDU enclosure, and AI server rack manufacturing.
    HARSLE lines support standard 42U liquid-cooled racks, rear-door heat exchanger assemblies, CDU skids, and custom depths from 800mm to 1200mm+. Mounting rail spacing follows EIA-310 19-inch / 21-inch standards, with customer-specific coolant routing layouts on request.
    Yes. Fiber laser cutting handles hose ports, gland cutouts, and manifold plate contours with ±0.1mm accuracy. CNC turret punching adds repeated mounting holes and vent patterns on identical chassis panels in the same line.
    For high-volume AI liquid cooling programs, a CNC turret punch press is strongly recommended. It delivers the fastest processing for repeated rail holes, GPU tray patterns, and vent grids on standardized liquid-cooled cabinet models.
    Sí. HARSLE ofrece servicios completos de instalación, puesta en marcha y capacitación de operadores in situ. Nuestra red de servicio global, presente en más de 100 países, garantiza asistencia técnica continua durante todo el ciclo de vida de la máquina.
    Sí. La configuración de la máquina, el nivel de automatización, la distribución de la fábrica y la capacidad de producción se pueden personalizar en función de su gama de productos, el espacio disponible y el plan de inversión.
    A typical liquid cooling cabinet line includes shearing, fiber laser cutting, CNC turret punching, panel bending, press brake bending, welding, deburring, powder coating, assembly, QC, and packing stations.
    Yes. Our engineers provide layout drawings optimized for liquid cooling enclosure material flow — from shearing and laser cutting through punching, bending, welding, coating, and assembly — with capacity planning based on your target daily output.
    Yes. Our team recommends suitable machine models and specifications according to your material thickness, liquid cooling cabinet dimensions, coolant layout complexity, target output, and automation requirements.
    Sí. HARSLE ofrece asistencia a clientes de todo el mundo con consultoría técnica, entrega de maquinaria, orientación para la instalación, formación, repuestos y servicio posventa.

    Start Your Liquid Cooling Cabinet
    Línea de producción hoy

    Get a custom factory layout, machine configuration, and turnkey liquid cooling cabinet line proposal from HARSLE engineers.

    Productos Vell
    🚀
    Respuesta rápida
    En 24 horas
    🆓
    Consulta gratuita
    Sin compromiso
    🌍
    Más de 100 países
    Servimos a nivel mundial.
    🏭
    Fábrica llave en mano
    Planificación incluida