Turnkey Sheet Metal Line for CDU Enclosures, Rear-Door Heat Exchangers, Manifold Panels & AI Liquid-Cooled Racks

Corte por láserPunzonado CNCDoblado de panelesLeak-Test ReadyHigh-Density AI

Liquid Cooling Cabinet Production Line
  • 100kW+Rack Thermal Class
  • ±0,1 mmLaser Cut Accuracy
  • CDU / RDHxEnclosure Types
  • LlaveroIngeniería de línea

Tendencia del mercado

Why Liquid Cooling Cabinet Manufacturing Is Growing

GPU-dense AI clusters and next-generation data centers are redefining thermal design. These drivers shape modern liquid cooling enclosure production lines.

AI and hyperscale data centers are shifting to liquid cooling to manage GPU thermal loads beyond air-cooled limits. HARSLE designs complete manufacturing lines for liquid cooling cabinet OEMs — from chassis blanking and coolant-path cutouts through precision forming, welded manifolds, coating, and assembly — scaled to your cabinet depth, flow layout, and daily output.

  • Expansión de los centros de datos de IA

    AI Data Center Expansion

    New AI-ready facilities deploy liquid-cooled racks at scale — driving demand for dedicated sheet metal lines that can produce chassis, manifolds, and CDU housings with repeatable precision.

  • Adopción de la refrigeración líquida

    Adopción de la refrigeración líquida

    Direct-to-chip, rear-door heat exchanger, and immersion cooling systems replace air-only designs — requiring new enclosure geometries, hose ports, and leak-test-ready weld quality.

  • Mayor densidad de racks

    Higher Rack Density & Power

    Modern GPU racks exceed 50–100 kW per cabinet. Stronger frames, deeper chassis, and integrated coolant distribution panels demand heavier-gauge forming and structural welding.

  • CDU and Facility Cooling Infrastructure

    CDU & Facility Cooling Infrastructure

    Coolant distribution units, pump skids, and manifold enclosures expand the product mix — manufactured on the same integrated line as server-side liquid cooling cabinets.

Flujo de fabricación

Liquid Cooling Cabinet Manufacturing Process

From raw sheet metal to a finished liquid cooling cabinet — chassis forming, coolant-path machining, welding, coating, and assembly in one integrated flow. Select a step to see what happens at each station.

Raw Sheet Metal — Liquid Cooling Cabinet

Paso 01 / 09Gabinete de refrigeración líquida

Raw Sheet Metal

Liquid cooling cabinet production starts with cold-rolled steel, stainless steel, or aluminum sheet. Material is graded by thickness and batch, then prepared for chassis and manifold panel machining.

  • Carbon steel, stainless steel & aluminum supported
  • Typical thickness: 1.0mm – 3.0mm for liquid-cooled chassis
  • Flatness and surface inspection before cutting

Soluciones de equipos

Machines for Liquid Cooling Cabinet Lines

Six machines arranged for liquid cooling cabinet lines — shearing and laser blanking first, CNC punch and panel bender for rack panels, then press brake, laser weld, and downstream coating support.

Máquina de corte de guillotina Cizallamiento

Máquina de corte de guillotina

Serie HARSLE QC11Y / QC12Y

Front-end of the liquid cooling line — shears carbon steel, stainless, and aluminum coils into flat blanks sized for laser cutting, punching, and forming stations downstream.

  • Chassis Sheet to Line-Ready Blanks
  • Bordes limpios · Mínima distorsión de la hoja
  • Steady Feed for 1.0–3.0mm Rack & CDU Sheet
Máquina de corte por láser de fibra Corte por láser

Máquina de corte por láser de fibra

Serie HARSLE EcoCut / ProCut

Blanks liquid-cooled chassis sections, manifold plates, hose port panels, and RDHx door contours before forming — the precision step for coolant-path and mounting cutouts on every liquid cooling cabinet line.

  • Coolant Port & Hose Gland Cutouts
  • Manifold & RDHx Panel Contours
  • Precisión de ±0,1 mm · Bajo desperdicio de material
Punzonadora de torreta CNC Equipo básico

Punzonadora de torreta CNC

Serie de torretas servo HARSLE D-ES300

The highest-volume station on a liquid cooling cabinet line — punches cage nut rails, GPU tray patterns, vent grids, and connector cutouts across thousands of identical chassis and side panels per shift.

  • 19" / 21" Rail & Tray Hole Patterns
  • Manifold Cover Vents & Louver Forms
  • Torreta de indexación automática · Precisión de ±0,05 mm
Panel Bender for Liquid Cooling Cabinets Dobladora de paneles

Panel Bender for Liquid Cooling Cabinets

Serie HARSLE AutoBend

Automatically forms rear-door heat exchanger housings, side plenum panels, and CDU covers in one pass — cutting labor and cycle time on standardized AI liquid-cooled rack models.

  • RDHx Door & Plenum One-Pass Forming
  • CDU Cover & Side Panel Production
  • Consistent Flange Width for Gasket Seams
Prensa plegadora CNC Prensa Plegadora

Prensa plegadora CNC

Serie MasterBend — DA69T / DA66T

Complements the panel bender — forms deep liquid-cooling chassis uprights, CDU frame sections, manifold brackets, and load-bearing stiffeners that panel benders do not complete in one cycle.

  • Deep Chassis Upright & Rail Bending
  • CDU Frame & Manifold Bracket Forming
  • Automatic Crowning for Long Rack Panels
Máquina de soldadura láser Soldadura láser

Máquina de soldadura láser

Serie HARSLE SmartWeld

Joins liquid cooling frames, manifold brackets, and fluid-path housings with clean, low-distortion seams — reducing grinding before coating and supporting leak-test-ready cabinet assemblies.

  • Chassis Frame & Manifold Bracket Welding
  • Costuras al ras · Menos trabajo posterior al rectificado
  • Stainless & Mild Steel Rack Structures

Gama de productos

Productos que ayudamos a fabricar

Liquid cooling enclosures and related sheet metal products produced on HARSLE manufacturing lines — built for AI data centers and hyperscale thermal infrastructure.

  • Gabinete de refrigeración líquida01

    Gabinete de refrigeración líquida

  • Gabinete para servidor GPU02

    Gabinete para servidor GPU

  • Rack de servidores de IA03

    Rack de servidores de IA

  • Gabinete para centro de datos04

    Gabinete para centro de datos

  • CDU Enclosure05

    CDU Enclosure

  • Rear-Door Heat Exchanger06

    Rear-Door Heat Exchanger

  • Manifold & Plenum Panel07

    Manifold & Plenum Panel

  • Sidecar Cooling Cabinet08

    Sidecar Cooling Cabinet

Nuestras ventajas

¿Por qué elegir HARSLE?

Engineered for AI liquid cooling programs — precision chassis forming, coolant-path machining, and leak-critical weld quality.

  • Precision Chassis Manufacturing

    Corte de ±0,1 mm · Curvatura de ±0,1°

    Laser and CNC forming tuned for hose ports, manifold interfaces, and rack rail spacing on high-density liquid-cooled cabinets.

  • Liquid Cooling Enclosure Know-How

    CDU · RDHx · Manifold

    Process parameters cover rear-door exchanger housings, CDU skids, and server-side cabinets on one integrated sheet metal line.

  • Ingeniería de líneas llave en mano

    Diseño · Equipamiento · Instalación

    From shearing and laser cutting through coating and assembly — one supplier plans, delivers, and commissions the full liquid cooling cabinet factory.

  • Red de servicios global

    Más de 100 países

    Worldwide installation, operator training, and spare parts support keep AI infrastructure and thermal OEM lines running without interruption.

  • 19" / 21" Rack Compatibility

    42U · Custom Depth · GPU Tray

    Equipment tuned for standard rack formats, deep liquid-cooled chassis depths, and customer-specific coolant routing layouts.

  • Capacidad multimaterial

    Acero · Acero inoxidable · Aluminio

    Process mild steel, stainless steel, and aluminum across cutting, punching, bending, welding, and coating on a single integrated line.

Planificación de fábricas

Diseño de la línea de producción de muestra

A reference layout for liquid cooling cabinet production — sheet preparation, laser cutting, CNC punching, forming, welding, coating, assembly, and final packing in one flow.

Liquid Cooling Cabinet Production Flow

  1. 01Almacenamiento y corte de láminasLine-ready chassis blanks
  2. 02Corte por láser de fibraChassis, ports, manifold panels
  3. 03Punzonado de torreta CNCRails, vents, connector cutouts
  4. 04Doblado de panelesRDHx doors, CDU covers, plenums
  5. 05Conformado con prensa plegadoraRieles, montantes, soportes
  6. 06Área de soldadura láserUnión de marcos y soportes
  7. 07Rectificado y recubrimientoDesbarbado y acabado en polvo
  8. 08Ensamblaje de gabinetes y control de calidadRails, ports, hose brackets
  9. 09Embalaje de gabinetes terminadosExport-ready liquid cooling cabinets

Request Your Custom LayoutView all products

Véalo en acción

Centro de vídeo

See HARSLE equipment processing liquid cooling chassis panels, manifold plates, and structural frames in live factory conditions.

  • Prensa plegadora HARSLE Genius

    MasterBend press brake forming deep liquid cooling chassis uprights and mounting rails for AI server enclosures.

  • Panel Bender — RDHx & Plenum Panels

    Automatic panel bender completing rear-door heat exchanger housings and plenum covers in a single pass — ideal for liquid cooling batch runs.

  • Laser Cutting — Chassis & Manifold Panels

    Fiber laser cutting liquid cooling chassis blanks, hose port panels, and manifold plates at full speed on a production line floor.

Huella global

Shipments & Customer Stories

Every shipment and customer story HARSLE publishes appears here automatically. Filter by machine or country.

  • 1,209Shipments published
  • 118Destination countries
  • 120Customer stories
  • LiveUpdated as we ship

Preguntas frecuentes

Preguntas frecuentes

Common questions about building a liquid cooling cabinet production line.

Ask our engineers

¿Qué materiales se pueden procesar?

HARSLE machines support Carbon Steel, Stainless Steel, and Aluminum — the three primary materials used in liquid cooling cabinet, CDU enclosure, and AI server rack manufacturing.

What cabinet types and depths are supported?

HARSLE lines support standard 42U liquid-cooled racks, rear-door heat exchanger assemblies, CDU skids, and custom depths from 800mm to 1200mm+. Mounting rail spacing follows EIA-310 19-inch / 21-inch standards, with customer-specific coolant routing layouts on request.

Can coolant port and manifold cutouts be produced?

Yes. Fiber laser cutting handles hose ports, gland cutouts, and manifold plate contours with ±0.1mm accuracy. CNC turret punching adds repeated mounting holes and vent patterns on identical chassis panels in the same line.

Is a turret punch press required for liquid cooling cabinet production?

For high-volume AI liquid cooling programs, a CNC turret punch press is strongly recommended. It delivers the fastest processing for repeated rail holes, GPU tray patterns, and vent grids on standardized liquid-cooled cabinet models.

¿Ofrecen servicios de instalación y capacitación?

Yes. HARSLE provides full on-site installation, commissioning, and operator training services. Our global service network in 100+ countries ensures ongoing technical support throughout the machine's lifecycle.

¿Se puede personalizar la línea de producción?

Sí. La configuración de la máquina, el nivel de automatización, la distribución de la fábrica y la capacidad de producción se pueden personalizar en función de su gama de productos, el espacio disponible y el plan de inversión.

What equipment is required for liquid cooling cabinet production?

A typical liquid cooling cabinet line includes shearing, fiber laser cutting, CNC turret punching, panel bending, press brake bending, welding, deburring, powder coating, assembly, QC, and packing stations.

Can HARSLE design a liquid cooling cabinet factory layout?

Yes. Our engineers provide layout drawings optimized for liquid cooling enclosure material flow — from shearing and laser cutting through punching, bending, welding, coating, and assembly — with capacity planning based on your target daily output.

¿Ofrecen recomendaciones sobre máquinas?

Yes. Our team recommends suitable machine models and specifications according to your material thickness, liquid cooling cabinet dimensions, coolant layout complexity, target output, and automation requirements.

¿Ofrecen servicio a clientes internacionales?

Sí. HARSLE ofrece asistencia a clientes de todo el mundo con consultoría técnica, entrega de maquinaria, orientación para la instalación, formación, repuestos y servicio posventa.

Comience

Solicitar una cotización

Start Your Liquid Cooling Cabinet Production Line Today — Get a custom factory layout, machine configuration, and turnkey liquid cooling cabinet line proposal from HARSLE engineers.

  • Selección de máquinasModel, series and options matched to your parts
  • Apoyo técnicoBend feasibility checked on your drawings
  • Cotización detalladaPrice, lead time, shipping and installation
  • Respuesta en 24 horasA real engineer replies within one business day

Tip: mention your material, thickness, largest part size and yearly volume for the most accurate quote.