Der Globaler Spannungsfinder shows the electricity supply in 172 countries: single-phase and three-phase voltage, frequency and plug types. Industrial machines run on the three-phase supply — for example 400 V 50 Hz in most of Europe, 380 V 50 Hz in China and 480 V or 208 V 60 Hz in the United States — so check it before you order a press brake, laser or shear.

  • Free, no sign-up
  • Instant results
  • Shareable link

Enter your values

Type the first letters to jump to a country.

Ergebnisse

Live
Industrial supply (three-phase)208 / 480 V · 60 Hzthree-phase industrial supply in United States
Single-phase voltage
120 V
Three-phase voltage
208 / 480 V
Frequenz
60 Hz
Plug types
Type A, B
Specify on your machine order
3-phase 208 V or 480 V, 60 Hz

Several voltages are in use. Ask your electrician for the voltage at the machine location before ordering.

Nominal national values. Factories may have a different transformer voltage (e.g. 415, 440, 460 or 690 V) — always confirm on site.

Why the voltage matters when buying a machine

Motors, hydraulic pumps, servo drives, laser sources and control transformers are built for a specific supply. A machine wired for 400 V 50 Hz will run motors about 20% faster on 60 Hz, and a 230 V three-phase motor connected to 400 V will burn out. HARSLE builds every machine for the customer’s voltage and frequency, so please tell us:

  • Three-phase voltage between phases (e.g. 380, 400, 415, 440, 480 V)
  • Frequency (50 or 60 Hz)
  • Whether a neutral conductor is available (3-phase 4-wire or 3-wire)

Verwenden Sie die electrical parameter calculator to size the breaker and cable once you know the supply.

How to use the Global Voltage Finder

  1. Wählen Sie die country where the machine will be installed.
  2. Read the three-phase voltage and frequency.
  3. Confirm the voltage at the factory and put it on your purchase order.

Voltage and frequency by country

LandRegionEinphasigDreiphasigFrequenzPlug types
AfghanistanAsia220 V380 V50 HzC, F
BangladeschAsia220 V380 V50 HzA, C, D, G, K
BhutanAsia230 V400 V50 HzC, D, F, G, M
BruneiAsia240 V415 V50 HzG
KambodschaAsia230 V400 V50 HzA, C, G
ChinaAsia220 V380 V50 HzA, C, I
Hong KongAsia220 V380 V50 HzD, G
IndienAsia230 V400 V50 HzC, D, M
IndonesienAsia230 V400 V50 HzC, F
JapanAsia100 V200 V50 (east) / 60 (west) HzA, B
KasachstanAsia220 V380 V50 HzC, F
KirgisistanAsia220 V380 V50 HzC, F
LaosAsia230 V400 V50 HzA, B, C, E, F
MacauAsia220 V380 V50 HzD, F, G
MalaysiaAsia240 V415 V50 HzG
MaldivesAsia230 V400 V50 HzC, D, G, J, K, L
MongoliaAsia230 V400 V50 HzC, E
MyanmarAsia230 V400 V50 HzA, C, D, G, I
NepalAsia230 V400 V50 HzC, D, M
North KoreaAsia220 V380 V50 HzA, C
PakistanAsia230 V400 V50 HzC, D
PhilippinenAsia220 V380 V60 HzA, B, C
SingapurAsia230 V400 V50 HzG
SüdkoreaAsia220 V380 V60 HzC, F
Sri LankaAsia230 V400 V50 HzD, G
TaiwanAsia110 V220 / 380 V60 HzA, B
TadschikistanAsia220 V380 V50 HzC, F
ThailandAsia230 V400 V50 HzA, B, C, F, O
Timor-LesteAsia220 V380 V50 HzC, E, F, I
TurkmenistanAsia220 V380 V50 HzB, C, F
UsbekistanAsia220 V380 V50 HzC, F
VietnamAsia220 V380 V50 HzA, C, F
BahrainMiddle East230 V400 V50 HzG
IranMiddle East230 V400 V50 HzC, F
IrakMiddle East230 V400 V50 HzC, D, G
IsraelMiddle East230 V400 V50 HzC, H, M
JordanienMiddle East230 V400 V50 HzB, C, D, F, G, J
KuwaitMiddle East240 V415 V50 HzC, G
LibanonMiddle East230 V400 V50 HzA, B, C, D, G
OmanMiddle East240 V415 V50 HzC, G
PalästinaMiddle East230 V400 V50 HzC, H
KatarMiddle East240 V415 V50 HzD, G
Saudi-ArabienMiddle East230 (127 legacy) V400 (220 legacy) V60 HzG
SyrienMiddle East220 V380 V50 HzC, E, L
TruthahnMiddle East230 V400 V50 HzC, F
United Arab EmiratesMiddle East230 V400 V50 HzC, D, G
YemenMiddle East230 V400 V50 HzA, D, G
AlbanienEurope230 V400 V50 HzC, F
ArmenienEurope230 V400 V50 HzC, F
AustriaEurope230 V400 V50 HzC, F
AserbaidschanEurope220 V380 V50 HzC, F
WeißrusslandEurope230 V400 V50 HzC, F
BelgienEurope230 V400 V50 HzC, E
Bosnia and HerzegovinaEurope230 V400 V50 HzC, F
BulgarienEurope230 V400 V50 HzC, F
KroatienEurope230 V400 V50 HzC, F
ZypernEurope230 V400 V50 HzG
Tschechische RepublikEurope230 V400 V50 HzC, E
DänemarkEurope230 V400 V50 HzC, E, F, K
EstlandEurope230 V400 V50 HzC, F
FinnlandEurope230 V400 V50 HzC, F
FrankreichEurope230 V400 V50 HzC, E
GeorgiaEurope220 V380 V50 HzC, F
DeutschlandEurope230 V400 V50 HzC, F
GriechenlandEurope230 V400 V50 HzC, F
UngarnEurope230 V400 V50 HzC, F
IcelandEurope230 V400 V50 HzC, F
IrlandEurope230 V400 V50 HzG
ItalienEurope230 V400 V50 HzC, F, L
KosovoEurope230 V400 V50 HzC, F
LettlandEurope230 V400 V50 HzC, F
LitauenEurope230 V400 V50 HzC, F
LuxembourgEurope230 V400 V50 HzC, F
MaltaEurope230 V400 V50 HzG
MoldawienEurope230 V400 V50 HzC, F
MontenegroEurope230 V400 V50 HzC, F
NiederlandeEurope230 V400 V50 HzC, F
North MacedoniaEurope230 V400 V50 HzC, F
NorwegenEurope230 V400 (some 230 IT) V50 HzC, F
PolenEurope230 V400 V50 HzC, E
PortugalEurope230 V400 V50 HzC, F
RumänienEurope230 V400 V50 HzC, F
RusslandEurope230 V400 V50 HzC, F
SerbienEurope230 V400 V50 HzC, F
SlowakeiEurope230 V400 V50 HzC, E
SlowenienEurope230 V400 V50 HzC, F
SpanienEurope230 V400 V50 HzC, F
SchwedenEurope230 V400 V50 HzC, F
SchweizEurope230 V400 V50 HzC, J
UkraineEurope230 V400 V50 HzC, F
United KingdomEurope230 V400 V50 HzG
AlgerienAfrica230 V400 V50 HzC, F
AngolaAfrica220 V380 V50 HzC
BeninAfrica220 V380 V50 HzC, E
BotswanaAfrica230 V400 V50 HzD, G, M
Burkina FasoAfrica220 V380 V50 HzC, E
BurundiAfrica220 V380 V50 HzC, E
KamerunAfrica220 V380 V50 HzC, E
TschadAfrica220 V380 V50 HzC, D, E, F
Congo (DRC)Africa220 V380 V50 HzC, D, E
Congo (Republic)Africa230 V400 V50 HzC, E
Côte d’IvoireAfrica220 V380 V50 HzC, E
DjiboutiAfrica220 V380 V50 HzC, E
ÄgyptenAfrica220 V380 V50 HzC, F
EritreaAfrica230 V400 V50 HzC, L
ÄthiopienAfrica220 V380 V50 HzC, E, F, L
GabonAfrica220 V380 V50 HzC
GhanaAfrica230 V400 V50 HzD, G
GuineaAfrica220 V380 V50 HzC, F, K
KeniaAfrica240 V415 V50 HzG
LiberiaAfrica120 V208 V60 HzA, B
LibyenAfrica230 V400 V50 HzC, L
MadagascarAfrica220 V380 V50 HzC, D, E, J, K
MalawiAfrica230 V400 V50 HzG
MaliAfrica220 V380 V50 HzC, E
MauritaniaAfrica220 V380 V50 HzC
MauritiusAfrica230 V400 V50 HzC, G
MarokkoAfrica220 V380 V50 HzC, E
MozambiqueAfrica220 V380 V50 HzC, F, M
NamibiaAfrica220 V380 V50 HzD, M
NigerAfrica220 V380 V50 HzA, B, C, D, E, F
NigeriaAfrica230 V415 V50 HzD, G
RuandaAfrica230 V400 V50 HzC, J
SenegalAfrica230 V400 V50 HzC, D, E, K
Sierra LeoneAfrica230 V400 V50 HzD, G
SomaliaAfrica220 V380 V50 HzC
SüdafrikaAfrica230 V400 V50 HzC, D, M, N
South SudanAfrica230 V400 V50 HzC, D
SudanAfrica230 V400 V50 HzC, D
TansaniaAfrica230 V400 V50 HzD, G
TogoAfrica220 V380 V50 HzC
TunesienAfrica230 V400 V50 HzC, E
UgandaAfrica240 V415 V50 HzG
SambiaAfrica230 V400 V50 HzC, D, G
SimbabweAfrica240 V415 V50 HzD, G
BahamasNorth America120 V208 V60 HzA, B
BarbadosNorth America115 V200 V50 HzA, B
BelizeNorth America110 / 220 V190 / 380 V60 HzA, B, G
KanadaNorth America120 V208 / 600 V60 HzA, B
Costa RicaNorth America120 V240 V60 HzA, B
CubaNorth America110 / 220 V190 / 440 V60 HzA, B, C, L
Dominican RepublicNorth America120 V208 V60 HzA, B
El SalvadorNorth America120 V200 V60 HzA, B
GuatemalaNorth America120 V208 V60 HzA, B
HaitiNorth America110 V190 V60 HzA, B
HondurasNorth America120 V208 V60 HzA, B
JamaicaNorth America110 V190 V50 HzA, B
MexikoNorth America127 V220 / 480 V60 HzA, B
NicaraguaNorth America120 V208 V60 HzA, B
PanamaNorth America120 V208 / 480 V60 HzA, B
Puerto RicoNorth America120 V208 / 480 V60 HzA, B
Trinidad and TobagoNorth America115 V230 / 400 V60 HzA, B
Vereinigte StaatenNorth America120 V208 / 480 V60 HzA, B
ArgentinienSouth America220 V380 V50 HzC, I
BolivienSouth America230 V400 V50 HzA, C
BrasilienSouth America127 / 220 V220 / 380 V60 HzC, N
ChileSouth America220 V380 V50 HzC, L
KolumbienSouth America120 V208 / 440 V60 HzA, B
EcuadorSouth America120 V208 V60 HzA, B
ParaguaySouth America220 V380 V50 HzC
PeruSouth America220 V220 / 380 V60 HzA, B, C
SurinameSouth America127 / 230 V220 / 400 V60 HzC, F
UruguaySouth America230 V400 V50 HzC, F, L
VenezuelaSouth America120 V208 / 480 V60 HzA, B
AustralienOceania230 V400 V50 HzI
FidschiOceania240 V415 V50 HzI
NeuseelandOceania230 V400 V50 HzI
Papua New GuineaOceania240 V415 V50 HzI
SamoaOceania230 V400 V50 HzI
Solomon IslandsOceania230 V415 V50 HzG, I
TongaOceania240 V415 V50 HzI
VanuatuOceania230 V400 V50 HzC, G, I

Frequently asked questions

Which countries use 60 Hz?

Most of the Americas (United States, Canada, Mexico, Brazil, Colombia, Peru…), Saudi Arabia, South Korea, the Philippines, Taiwan, Liberia and western Japan. Nearly all other countries use 50 Hz.

What is the industrial voltage in Europe?

400 V three-phase, 50 Hz, with 230 V single-phase, across the EU, the UK and most neighbouring countries.

Can a 50 Hz machine run on 60 Hz?

Only if the motors, pumps and transformers are rated for it. Motors run about 20% faster on 60 Hz, which changes pump flow and fan speed. Order the machine for the local frequency.

What voltage does a press brake need?

Industrial press brakes, shears and lasers use the local three-phase supply, for example 380 V 50 Hz in China, 400 V 50 Hz in Europe or 480 V 60 Hz in the US. Single-phase machines are limited to very small sizes.

Reviewed by the HARSLE engineering team · Last updated October 2026. Results are engineering estimates; confirm critical values with your machine and tooling documentation.

Industrial supply (three-phase)—