O Localizador de Voltagem Global shows the electricity supply in 172 countries: single-phase and three-phase voltage, frequency and plug types. Industrial machines run on the three-phase supply — for example 400 V 50 Hz in most of Europe, 380 V 50 Hz in China and 480 V or 208 V 60 Hz in the United States — so check it before you order a press brake, laser or shear.

  • Free, no sign-up
  • Instant results
  • Shareable link

Enter your values

Type the first letters to jump to a country.

Resultados

Live
Industrial supply (three-phase)208 / 480 V · 60 Hzthree-phase industrial supply in United States
Single-phase voltage
120 V
Three-phase voltage
208 / 480 V
Freqüência
60 Hz
Plug types
Type A, B
Specify on your machine order
3-phase 208 V or 480 V, 60 Hz

Several voltages are in use. Ask your electrician for the voltage at the machine location before ordering.

Nominal national values. Factories may have a different transformer voltage (e.g. 415, 440, 460 or 690 V) — always confirm on site.

Why the voltage matters when buying a machine

Motors, hydraulic pumps, servo drives, laser sources and control transformers are built for a specific supply. A machine wired for 400 V 50 Hz will run motors about 20% faster on 60 Hz, and a 230 V three-phase motor connected to 400 V will burn out. HARSLE builds every machine for the customer’s voltage and frequency, so please tell us:

  • Three-phase voltage between phases (e.g. 380, 400, 415, 440, 480 V)
  • Frequency (50 or 60 Hz)
  • Whether a neutral conductor is available (3-phase 4-wire or 3-wire)

Use o electrical parameter calculator to size the breaker and cable once you know the supply.

How to use the Global Voltage Finder

  1. Selecione o country where the machine will be installed.
  2. Read the three-phase voltage and frequency.
  3. Confirm the voltage at the factory and put it on your purchase order.

Voltage and frequency by country

PaísRegionMonofásicoTrifásicoFreqüênciaPlug types
AfghanistanAsia220 V380 V50 HzC, F
BangladeshAsia220 V380 V50 HzA, C, D, G, K
BhutanAsia230 V400 V50 HzC, D, F, G, M
BruneiAsia240 V415 V50 HzG
CambojaAsia230 V400 V50 HzA, C, G
ChinaAsia220 V380 V50 HzA, C, I
Hong KongAsia220 V380 V50 HzD, G
ÍndiaAsia230 V400 V50 HzC, D, M
IndonésiaAsia230 V400 V50 HzC, F
JapanAsia100 V200 V50 (east) / 60 (west) HzA, B
CazaquistãoAsia220 V380 V50 HzC, F
QuirguistãoAsia220 V380 V50 HzC, F
LaosAsia230 V400 V50 HzA, B, C, E, F
MacauAsia220 V380 V50 HzD, F, G
MalásiaAsia240 V415 V50 HzG
MaldivesAsia230 V400 V50 HzC, D, G, J, K, L
MongoliaAsia230 V400 V50 HzC, E
MianmarAsia230 V400 V50 HzA, C, D, G, I
NepalAsia230 V400 V50 HzC, D, M
North KoreaAsia220 V380 V50 HzA, C
PaquistãoAsia230 V400 V50 HzC, D
FilipinasAsia220 V380 V60 HzA, B, C
CingapuraAsia230 V400 V50 HzG
Coréia do SulAsia220 V380 V60 HzC, F
Sri LankaAsia230 V400 V50 HzD, G
TaiwanAsia110 V220 / 380 V60 HzA, B
TajiquistãoAsia220 V380 V50 HzC, F
TailândiaAsia230 V400 V50 HzA, B, C, F, O
Timor-LesteAsia220 V380 V50 HzC, E, F, I
TurcomenistãoAsia220 V380 V50 HzB, C, F
UzbequistãoAsia220 V380 V50 HzC, F
VietnãAsia220 V380 V50 HzA, C, F
BahreinMiddle East230 V400 V50 HzG
IrãMiddle East230 V400 V50 HzC, F
IraqueMiddle East230 V400 V50 HzC, D, G
IsraelMiddle East230 V400 V50 HzC, H, M
JordâniaMiddle East230 V400 V50 HzB, C, D, F, G, J
KuwaitMiddle East240 V415 V50 HzC, G
LíbanoMiddle East230 V400 V50 HzA, B, C, D, G
OmanMiddle East240 V415 V50 HzC, G
PalestinaMiddle East230 V400 V50 HzC, H
CatarMiddle East240 V415 V50 HzD, G
Arábia SauditaMiddle East230 (127 legacy) V400 (220 legacy) V60 HzG
SíriaMiddle East220 V380 V50 HzC, E, L
PeruMiddle East230 V400 V50 HzC, F
United Arab EmiratesMiddle East230 V400 V50 HzC, D, G
YemenMiddle East230 V400 V50 HzA, D, G
AlbâniaEurope230 V400 V50 HzC, F
ArmêniaEurope230 V400 V50 HzC, F
AustriaEurope230 V400 V50 HzC, F
AzerbaijãoEurope220 V380 V50 HzC, F
BelarusEurope230 V400 V50 HzC, F
BélgicaEurope230 V400 V50 HzC, E
Bosnia and HerzegovinaEurope230 V400 V50 HzC, F
BulgáriaEurope230 V400 V50 HzC, F
CroáciaEurope230 V400 V50 HzC, F
ChipreEurope230 V400 V50 HzG
República TchecaEurope230 V400 V50 HzC, E
DinamarcaEurope230 V400 V50 HzC, E, F, K
EstôniaEurope230 V400 V50 HzC, F
FinlândiaEurope230 V400 V50 HzC, F
FrançaEurope230 V400 V50 HzC, E
GeórgiaEurope220 V380 V50 HzC, F
AlemanhaEurope230 V400 V50 HzC, F
GréciaEurope230 V400 V50 HzC, F
HungriaEurope230 V400 V50 HzC, F
IcelandEurope230 V400 V50 HzC, F
IrlandaEurope230 V400 V50 HzG
ItáliaEurope230 V400 V50 HzC, F, L
KosovoEurope230 V400 V50 HzC, F
LetôniaEurope230 V400 V50 HzC, F
LituâniaEurope230 V400 V50 HzC, F
LuxembourgEurope230 V400 V50 HzC, F
MaltaEurope230 V400 V50 HzG
MoldáviaEurope230 V400 V50 HzC, F
MontenegroEurope230 V400 V50 HzC, F
HolandaEurope230 V400 V50 HzC, F
North MacedoniaEurope230 V400 V50 HzC, F
NoruegaEurope230 V400 (some 230 IT) V50 HzC, F
PolôniaEurope230 V400 V50 HzC, E
PortugalEurope230 V400 V50 HzC, F
RomêniaEurope230 V400 V50 HzC, F
RússiaEurope230 V400 V50 HzC, F
SérviaEurope230 V400 V50 HzC, F
EslováquiaEurope230 V400 V50 HzC, E
EslovêniaEurope230 V400 V50 HzC, F
EspanhaEurope230 V400 V50 HzC, F
SuéciaEurope230 V400 V50 HzC, F
SuíçaEurope230 V400 V50 HzC, J
UcrâniaEurope230 V400 V50 HzC, F
United KingdomEurope230 V400 V50 HzG
ArgéliaAfrica230 V400 V50 HzC, F
AngolaAfrica220 V380 V50 HzC
BeninAfrica220 V380 V50 HzC, E
BotswanaAfrica230 V400 V50 HzD, G, M
Burkina FasoAfrica220 V380 V50 HzC, E
BurundiAfrica220 V380 V50 HzC, E
CamarõesAfrica220 V380 V50 HzC, E
ChadeAfrica220 V380 V50 HzC, D, E, F
Congo (DRC)Africa220 V380 V50 HzC, D, E
Congo (Republic)Africa230 V400 V50 HzC, E
Côte d’IvoireAfrica220 V380 V50 HzC, E
DjibutiAfrica220 V380 V50 HzC, E
EgitoAfrica220 V380 V50 HzC, F
EritreiaAfrica230 V400 V50 HzC, L
EtiópiaAfrica220 V380 V50 HzC, E, F, L
GabonAfrica220 V380 V50 HzC
GhanaAfrica230 V400 V50 HzD, G
GuinéAfrica220 V380 V50 HzC, F, K
QuêniaAfrica240 V415 V50 HzG
LiberiaAfrica120 V208 V60 HzA, B
LíbiaAfrica230 V400 V50 HzC, L
MadagáscarAfrica220 V380 V50 HzC, D, E, J, K
MalawiAfrica230 V400 V50 HzG
MaliAfrica220 V380 V50 HzC, E
MauritaniaAfrica220 V380 V50 HzC
MauritiusAfrica230 V400 V50 HzC, G
MarrocosAfrica220 V380 V50 HzC, E
MozambiqueAfrica220 V380 V50 HzC, F, M
NamibiaAfrica220 V380 V50 HzD, M
NigerAfrica220 V380 V50 HzA, B, C, D, E, F
NigériaAfrica230 V415 V50 HzD, G
RuandaAfrica230 V400 V50 HzC, J
SenegalAfrica230 V400 V50 HzC, D, E, K
Sierra LeoneAfrica230 V400 V50 HzD, G
SomaliaAfrica220 V380 V50 HzC
África do SulAfrica230 V400 V50 HzC, D, M, N
South SudanAfrica230 V400 V50 HzC, D
SudãoAfrica230 V400 V50 HzC, D
TanzâniaAfrica230 V400 V50 HzD, G
IrAfrica220 V380 V50 HzC
TunísiaAfrica230 V400 V50 HzC, E
UgandaAfrica240 V415 V50 HzG
ZâmbiaAfrica230 V400 V50 HzC, D, G
ZimbábueAfrica240 V415 V50 HzD, G
BahamasNorth America120 V208 V60 HzA, B
BarbadosNorth America115 V200 V50 HzA, B
BelizeNorth America110 / 220 V190 / 380 V60 HzA, B, G
CanadáNorth America120 V208 / 600 V60 HzA, B
Costa RicaNorth America120 V240 V60 HzA, B
CubaNorth America110 / 220 V190 / 440 V60 HzA, B, C, L
Dominican RepublicNorth America120 V208 V60 HzA, B
El SalvadorNorth America120 V200 V60 HzA, B
GuatemalaNorth America120 V208 V60 HzA, B
HaitiNorth America110 V190 V60 HzA, B
HondurasNorth America120 V208 V60 HzA, B
JamaicaNorth America110 V190 V50 HzA, B
MéxicoNorth America127 V220 / 480 V60 HzA, B
NicaráguaNorth America120 V208 V60 HzA, B
PanamáNorth America120 V208 / 480 V60 HzA, B
Porto RicoNorth America120 V208 / 480 V60 HzA, B
Trinidad and TobagoNorth America115 V230 / 400 V60 HzA, B
Estados UnidosNorth America120 V208 / 480 V60 HzA, B
ArgentinaSouth America220 V380 V50 HzC, I
BolíviaSouth America230 V400 V50 HzA, C
BrasilSouth America127 / 220 V220 / 380 V60 HzC, N
ChileSouth America220 V380 V50 HzC, L
ColômbiaSouth America120 V208 / 440 V60 HzA, B
EquadorSouth America120 V208 V60 HzA, B
ParaguaiSouth America220 V380 V50 HzC
PeruSouth America220 V220 / 380 V60 HzA, B, C
SurinameSouth America127 / 230 V220 / 400 V60 HzC, F
UruguaiSouth America230 V400 V50 HzC, F, L
VenezuelaSouth America120 V208 / 480 V60 HzA, B
AustráliaOceania230 V400 V50 HzI
FijiOceania240 V415 V50 HzI
Nova ZelândiaOceania230 V400 V50 HzI
Papua New GuineaOceania240 V415 V50 HzI
SamoaOceania230 V400 V50 HzI
Solomon IslandsOceania230 V415 V50 HzG, I
TongaOceania240 V415 V50 HzI
VanuatuOceania230 V400 V50 HzC, G, I

Frequently asked questions

Which countries use 60 Hz?

Most of the Americas (United States, Canada, Mexico, Brazil, Colombia, Peru…), Saudi Arabia, South Korea, the Philippines, Taiwan, Liberia and western Japan. Nearly all other countries use 50 Hz.

What is the industrial voltage in Europe?

400 V three-phase, 50 Hz, with 230 V single-phase, across the EU, the UK and most neighbouring countries.

Can a 50 Hz machine run on 60 Hz?

Only if the motors, pumps and transformers are rated for it. Motors run about 20% faster on 60 Hz, which changes pump flow and fan speed. Order the machine for the local frequency.

What voltage does a press brake need?

Industrial press brakes, shears and lasers use the local three-phase supply, for example 380 V 50 Hz in China, 400 V 50 Hz in Europe or 480 V 60 Hz in the US. Single-phase machines are limited to very small sizes.

Reviewed by the HARSLE engineering team · Last updated October 2026. Results are engineering estimates; confirm critical values with your machine and tooling documentation.

Industrial supply (three-phase)—