Lösungen für Produktionslinien · HARSLE

Vollständig Liquid Cooling Cabinet Produktionslinie

Turnkey Sheet Metal Line for CDU Enclosures, Rear-Door Heat Exchangers, Manifold Panels & AI Liquid-Cooled Racks

LaserschneidenCNC-StanzenBlechbiegenLeak-Test ReadyHigh-Density AI

Produktionslinie für Flüssigkeitskühlschränke
  • 100kW+Rack Thermal Class
  • ±0,1 mmLaser Cut Accuracy
  • CDU / RDHxEnclosure Types
  • SchlüsselfertigLeitungsplanung

Markttrend

Why Liquid Cooling Cabinet Manufacturing Is Growing

GPU-dense AI clusters and next-generation data centers are redefining thermal design. These drivers shape modern liquid cooling enclosure production lines.

AI and hyperscale data centers are shifting to liquid cooling to manage GPU thermal loads beyond air-cooled limits. HARSLE designs complete manufacturing lines for liquid cooling cabinet OEMs — from chassis blanking and coolant-path cutouts through precision forming, welded manifolds, coating, and assembly — scaled to your cabinet depth, flow layout, and daily output.

  • AI Data Centers Expansion

    AI Data Center Expansion

    New AI-ready facilities deploy liquid-cooled racks at scale — driving demand for dedicated sheet metal lines that can produce chassis, manifolds, and CDU housings with repeatable precision.

  • Liquid Cooling Adoption

    Liquid Cooling Adoption

    Direct-to-chip, rear-door heat exchanger, and immersion cooling systems replace air-only designs — requiring new enclosure geometries, hose ports, and leak-test-ready weld quality.

  • Higher Rack Density

    Higher Rack Density & Power

    Modern GPU racks exceed 50–100 kW per cabinet. Stronger frames, deeper chassis, and integrated coolant distribution panels demand heavier-gauge forming and structural welding.

  • CDU and Facility Cooling Infrastructure

    CDU & Facility Cooling Infrastructure

    Coolant distribution units, pump skids, and manifold enclosures expand the product mix — manufactured on the same integrated line as server-side liquid cooling cabinets.

Fertigungsablauf

Liquid Cooling Cabinet Manufacturing Process

From raw sheet metal to a finished liquid cooling cabinet — chassis forming, coolant-path machining, welding, coating, and assembly in one integrated flow. Select a step to see what happens at each station.

Raw Sheet Metal — Liquid Cooling Cabinet

Schritt 01 / 09Liquid Cooling Cabinet

Raw Sheet Metal

Liquid cooling cabinet production starts with cold-rolled steel, stainless steel, or aluminum sheet. Material is graded by thickness and batch, then prepared for chassis and manifold panel machining.

  • Carbon steel, stainless steel & aluminum supported
  • Typical thickness: 1.0mm – 3.0mm for liquid-cooled chassis
  • Flatness and surface inspection before cutting

Ausrüstungslösungen

Machines for Liquid Cooling Cabinet Lines

Six machines arranged for liquid cooling cabinet lines — shearing and laser blanking first, CNC punch and panel bender for rack panels, then press brake, laser weld, and downstream coating support.

Guillotine-Schermaschine Scheren

Guillotine-Schermaschine

HARSLE QC11Y / QC12Y Serie

Front-end of the liquid cooling line — shears carbon steel, stainless, and aluminum coils into flat blanks sized for laser cutting, punching, and forming stations downstream.

  • Chassis Sheet to Line-Ready Blanks
  • Saubere Kanten · Minimale Blattverzerrung
  • Steady Feed for 1.0–3.0mm Rack & CDU Sheet
Faserlaser-Schneidemaschine Laserschneiden

Faserlaser-Schneidemaschine

HARSLE EcoCut / ProCut Serie

Blanks liquid-cooled chassis sections, manifold plates, hose port panels, and RDHx door contours before forming — the precision step for coolant-path and mounting cutouts on every liquid cooling cabinet line.

  • Coolant Port & Hose Gland Cutouts
  • Manifold & RDHx Panel Contours
  • ±0,1 mm Genauigkeit · Geringer Materialverbrauch
CNC-Revolverstanzpresse Kernausrüstung

CNC-Revolverstanzpresse

HARSLE D-ES300 Servo-Turmserie

The highest-volume station on a liquid cooling cabinet line — punches cage nut rails, GPU tray patterns, vent grids, and connector cutouts across thousands of identical chassis and side panels per shift.

  • 19" / 21" Rail & Tray Hole Patterns
  • Manifold Cover Vents & Louver Forms
  • Automatischer Indexierturm · ±0,05 mm Genauigkeit
Panel Bender for Liquid Cooling Cabinets Blechbieger

Panel Bender for Liquid Cooling Cabinets

HARSLE AutoBend-Serie

Automatically forms rear-door heat exchanger housings, side plenum panels, and CDU covers in one pass — cutting labor and cycle time on standardized AI liquid-cooled rack models.

  • RDHx Door & Plenum One-Pass Forming
  • CDU Cover & Side Panel Production
  • Consistent Flange Width for Gasket Seams
CNC-Abkantpresse Abkantpresse

CNC-Abkantpresse

MasterBend-Serie — DA69T / DA66T

Complements the panel bender — forms deep liquid-cooling chassis uprights, CDU frame sections, manifold brackets, and load-bearing stiffeners that panel benders do not complete in one cycle.

  • Deep Chassis Upright & Rail Bending
  • CDU Frame & Manifold Bracket Forming
  • Automatic Crowning for Long Rack Panels
Laserschweißgerät Laserschweißen

Laserschweißgerät

HARSLE SmartWeld-Serie

Joins liquid cooling frames, manifold brackets, and fluid-path housings with clean, low-distortion seams — reducing grinding before coating and supporting leak-test-ready cabinet assemblies.

  • Chassis Frame & Manifold Bracket Welding
  • Bündige Nähte · Weniger Nachbearbeitung
  • Stainless & Mild Steel Rack Structures

Produktpalette

Produkte, deren Herstellung wir unterstützen

Liquid cooling enclosures and related sheet metal products produced on HARSLE manufacturing lines — built for AI data centers and hyperscale thermal infrastructure.

  • Liquid Cooling Cabinet01

    Liquid Cooling Cabinet

  • GPU Server Cabinet02

    GPU Server Cabinet

  • AI Server Rack03

    AI Server Rack

  • Data Center Cabinet04

    Data Center Cabinet

  • CDU Enclosure05

    CDU Enclosure

  • Rear-Door Heat Exchanger06

    Rear-Door Heat Exchanger

  • Manifold & Plenum Panel07

    Manifold & Plenum Panel

  • Sidecar Cooling Cabinet08

    Sidecar Cooling Cabinet

Unsere Vorteile

Warum HARSLE wählen

Engineered for AI liquid cooling programs — precision chassis forming, coolant-path machining, and leak-critical weld quality.

  • Precision Chassis Manufacturing

    ±0.1mm Cut · ±0.1° Bend

    Laser and CNC forming tuned for hose ports, manifold interfaces, and rack rail spacing on high-density liquid-cooled cabinets.

  • Liquid Cooling Enclosure Know-How

    CDU · RDHx · Manifold

    Process parameters cover rear-door exchanger housings, CDU skids, and server-side cabinets on one integrated sheet metal line.

  • Turnkey Line Engineering

    Layout · Ausrüstung · Installation

    From shearing and laser cutting through coating and assembly — one supplier plans, delivers, and commissions the full liquid cooling cabinet factory.

  • Globales Servicenetzwerk

    Mehr als 100 Länder

    Worldwide installation, operator training, and spare parts support keep AI infrastructure and thermal OEM lines running without interruption.

  • 19" / 21" Rack Compatibility

    42U · Custom Depth · GPU Tray

    Equipment tuned for standard rack formats, deep liquid-cooled chassis depths, and customer-specific coolant routing layouts.

  • Multi-Material Capability

    Steel · Stainless · Aluminum

    Process mild steel, stainless steel, and aluminum across cutting, punching, bending, welding, and coating on a single integrated line.

Fabrikplanung

Sample Production Line Layout

A reference layout for liquid cooling cabinet production — sheet preparation, laser cutting, CNC punching, forming, welding, coating, assembly, and final packing in one flow.

Liquid Cooling Cabinet Production Flow

  1. 01Blechlagerung & ScherenLine-ready chassis blanks
  2. 02FaserlaserschneidenChassis, ports, manifold panels
  3. 03CNC-RevolverstanzenRails, vents, connector cutouts
  4. 04BlechbiegenRDHx doors, CDU covers, plenums
  5. 05AbkantpressenRails, uprights, brackets
  6. 06LaserschweißbereichFrame and bracket joining
  7. 07Schleifen & BeschichtenEntgraten und Pulverbeschichten
  8. 08Cabinet Assembly & QCRails, ports, hose brackets
  9. 09Finished Cabinet PackingExport-ready liquid cooling cabinets

Fordern Sie Ihr individuelles Layout anAlle Produkte ansehen

Sehen Sie es in Aktion

Videozentrum

See HARSLE equipment processing liquid cooling chassis panels, manifold plates, and structural frames in live factory conditions.

  • HARSLE Genius Abkantpresse

    MasterBend press brake forming deep liquid cooling chassis uprights and mounting rails for AI server enclosures.

  • Panel Bender — RDHx & Plenum Panels

    Automatic panel bender completing rear-door heat exchanger housings and plenum covers in a single pass — ideal for liquid cooling batch runs.

  • Laser Cutting — Chassis & Manifold Panels

    Fiber laser cutting liquid cooling chassis blanks, hose port panels, and manifold plates at full speed on a production line floor.

Globaler Fußabdruck

Lieferungen & Kundengeschichten

Alle von HARSLE veröffentlichten Sendungen und Kundengeschichten erscheinen hier automatisch. Filtern Sie nach Maschine oder Land.

  • 1,243Veröffentlichte Sendungen
  • 120Zielländer
  • 125Kundengeschichten
  • LiveAktualisiert, sobald wir es versenden

Häufig gestellte Fragen

Häufig gestellte Fragen

Common questions about building a liquid cooling cabinet production line.

Fragen Sie unsere Ingenieure

Welche Materialien können verarbeitet werden?

HARSLE machines support Carbon Steel, Stainless Steel, and Aluminum — the three primary materials used in liquid cooling cabinet, CDU enclosure, and AI server rack manufacturing.

What cabinet types and depths are supported?

HARSLE lines support standard 42U liquid-cooled racks, rear-door heat exchanger assemblies, CDU skids, and custom depths from 800mm to 1200mm+. Mounting rail spacing follows EIA-310 19-inch / 21-inch standards, with customer-specific coolant routing layouts on request.

Can coolant port and manifold cutouts be produced?

Yes. Fiber laser cutting handles hose ports, gland cutouts, and manifold plate contours with ±0.1mm accuracy. CNC turret punching adds repeated mounting holes and vent patterns on identical chassis panels in the same line.

Is a turret punch press required for liquid cooling cabinet production?

For high-volume AI liquid cooling programs, a CNC turret punch press is strongly recommended. It delivers the fastest processing for repeated rail holes, GPU tray patterns, and vent grids on standardized liquid-cooled cabinet models.

Bieten Sie Installation und Schulung an?

Yes. HARSLE provides full on-site installation, commissioning, and operator training services. Our global service network in 100+ countries ensures ongoing technical support throughout the machine's lifecycle.

Lässt sich die Produktionslinie individuell anpassen?

Yes. Machine configuration, automation level, factory layout, and production capacity can be customized based on your product range, floor space, and investment plan.

What equipment is required for liquid cooling cabinet production?

A typical liquid cooling cabinet line includes shearing, fiber laser cutting, CNC turret punching, panel bending, press brake bending, welding, deburring, powder coating, assembly, QC, and packing stations.

Can HARSLE design a liquid cooling cabinet factory layout?

Yes. Our engineers provide layout drawings optimized for liquid cooling enclosure material flow — from shearing and laser cutting through punching, bending, welding, coating, and assembly — with capacity planning based on your target daily output.

Bieten Sie Maschinenempfehlungen an?

Yes. Our team recommends suitable machine models and specifications according to your material thickness, liquid cooling cabinet dimensions, coolant layout complexity, target output, and automation requirements.

Do you support overseas customers?

Yes. HARSLE supports customers worldwide with technical consultation, machine delivery, installation guidance, training, spare parts, and after-sales service.

Los geht's

Angebot anfordern

Start Your Liquid Cooling Cabinet Production Line Today — Get a custom factory layout, machine configuration, and turnkey liquid cooling cabinet line proposal from HARSLE engineers.

  • MaschinenauswahlModell, Baureihe und Optionen, die auf Ihre Teile abgestimmt sind
  • Technische UnterstützungDie Machbarkeit der Biegung wurde anhand Ihrer Zeichnungen geprüft.
  • Detailliertes AngebotPreis, Lieferzeit, Versand und Installation
  • 24-Stunden-ReaktionEin echter Ingenieur antwortet innerhalb eines Werktages.

Tipp: Geben Sie für ein möglichst genaues Angebot das Material, die Dicke, die größte Teilegröße und das jährliche Produktionsvolumen an.