Views: 44 Author: Site Editor Publish Time: 2018-12-25 Origin: Site
The reason:
Electrical wiring is not secure or wrong.
⒈Control mailbox pressure is insufficient.
⒉The mailbox is not enough.
Method of exclusion:
⒈Check the electrical.
⒉Appropriately increase the control oil pressure to 1.5MPa.
⒊Add oil.
The reason:
⒈Accumulate air or pump in the system.
⒉Improper adjustment of precision or lack of oil in the column.
Method of exclusion:
⒈Check if the pump suction pipe is in the air, then move up and down several times and pressurize.
⒉Add oil to the column and readjust the accuracy.
●The slider is pressed at a slow speed:
The reason:
⒈Supporting power is too large.
Method of exclusion:
⒈Adjust the back pressure valve so that the upper chamber is not pressurized, the maximum is not more than 1MPa.
●Seriously slipped under the slider after parking:
The reason:
⒈The notch seal ring leaks.
⒉The pressure valve adjusts the pressure or the valve port is not strict.
Method of exclusion:
⒈Observe the gap and find that the oil leakage should be replaced;
⒉Adjust the pressure check valve port.
●The pressure gauge pointer swings badly:
The reason:
⒈There is air in the pressure gauge oil circuit.
⒉Pipeline mechanical vibration.
⒊Pressure gauge damage.
Method of exclusion:
⒈Loosen the pipe joint slightly when pressing up, deflate.
⒉Catch the pipe.
⒊ Replace the pressure gauge.
●High pressure stroke speed is not enough, the pressure is slow.
The reason:
⒈The high pressure pump flow rate is too small.
⒉Pump wear or burn.
⒊The system is leaking seriously.
Method of exclusion:
⒈Adjust according to the instructions of the pump. The pump eccentricity can be adjusted to 5 grids at 25MPa.
⒉If the leakage of the pump return port is large, the inspection should be removed.
⒊First check if the filling valve is closed and then check whether the seals of each component are damaged.
●The pressure drop is too fast when holding pressure.
The reason:
⒈The valve ports involved in the pressure keeping are not strict or the pipeline leaks oil.
⒉The seal inside the cylinder is damaged.
Method of exclusion:
⒈Check the filling valve, the pressure and pressure relief valve sealing and research.
⒉Replace the seal ring.